Suspension Mounting
① Wire Suspension Hanging Points (4 mm hole size)
② VESA Mounting Holes
4-Point Wire Suspension
Secure the microphone to the ceiling using braided metal cable or other high-strength wire. Use the 4 integrated hanging
points on the back of the microphone to securely attach the cable. The hole size in the hanging points is 4 mm (0.15 in).
VESA Standardized Mounting
The rear plate on the microphone has 4 threaded holes for attaching the microphone to a VESA mounting device. The mount­
ing holes follow the VESA MIS-D standard:
Screw specification: M4 thread (Microphone threaded hole depth = 9.15 mm)
Hole spacing: 100 mm (square)
Hard Ceiling Mounting
You can mount the microphone in hard ceilings without a tile grid using the A910-HCM accessory.
Learn more at www.shure.com.
Cable Management
To keep the Ethernet cable out of view, use the appropriate method based on the installation type.
Installation
Ceiling grid
VESA (pole mounting)
4-point wire suspension
Hard ceiling
Cable Solution
Run the cable above the ceiling grid
Guide the cable through the pole to run it above the ceiling
grid
Use cable ties to attach the CAT5 cable along one of the
hanging wires
Run the cable above the ceiling