Mount the Access Point Transceiver

The directional antennas of the access point send and receive the RF signal in a cardioid pattern with the greatest sensitivity
toward the face of the device. Always aim this side toward the microphone coverage area.
Select a Location for the Access Point
The access point is typically mounted to a ceiling or wall near the microphone coverage area.
Use the following best-practices when selecting a location for the device:
Direct the face of the access point toward the intended microphone coverage area.
Position the access point so there is nothing obstructing a line of sight to the microphones.
Keep the device away from large metal objects.
Keep at least eight feet between access points.
Mount with the reset button accessible, as it may be useful for troubleshooting.