REMOVING THE CONTROL POWER SUPPLY AND
THE POWER SUPPLY TRANSFORMER
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug range or disconnect power.
2.
Remove the control panel and rotate it
forward (see page 4-2, steps 2a through
2d for the procedure).
3.
Remove the cooktop glass (see page 4-5
for the procedure).
Power Supply Transformer
4.
To remove the control power supply:
a) Remove the control power supply
mounting screw from the bracket.
b) Disconnect the wire connectors from
the control power supply terminals, and
remove the module from the unit.
Control Power Supply
Control Power
Supply Screw
4-7
P2 P1 T3
P7
T2
5.
To remove the power supply transformer:
a) Disconnect the primary wire connector
from the wire harness, and remove the
wires and connector from the wire tie.
b) Disconnect the secondary wire con-
nector from electronic oven control
(EOC) connector P1, and the two blue
wires from the control thermal switch
terminals.
c) Remove the power supply transformer
screw from the bracket and remove the
transformer.
Screw
Power
Supply
Transformer
Primary Wire Connector
P6
P3
J1
T1A
T1B
P5
Secondary Wires
At EOC-P1
P4