KitchenAid KESI901PBL Technical Education page 20

Self-cleaning slide - in/freestanding electric ranges
Table of Contents

Advertisement

3.
Use a 1/4" nut driver and remove the hex
washer head screws from the terminal
blocks.
4.
Connect the neutral (center) wire to the
center terminal connector using one of the
hex washer head screws. Securely tighten
screw for proper electrical connection.
D
C
B
A
A. Line 1
B. Green ground wire
C. Ground-link screw
D. Hex washer head screw
E. Silver-colored terminal
block screw
5.
Connect the other 2 wires (lines 1 and 2)
to the outer aluminum terminal blocks.
6.
Securely tighten screws for proper electri-
cal connection.
7.
Tighten strain relief screws.
8.
Replace terminal block cover.
9.
Plug in range or reconnect power.
E
F
G
H
I
F. Ground-link
G. Neutral (center) wire
H. Line 2
I. UL listed strain relief and
40 amp range power
supply cord
3-wire connection: Power supply cord
Use this method only if local codes permit
connecting cabinet-ground conductor to neu-
tral wire of power supply cord.
1.
Use a 1/4" nut driver and remove the hex
washer head screws from the aluminum
terminal blocks.
2.
Connect the neutral (center) wire to the
center terminal connector using one of the
hex washer head screws. Securely tighten
screw for proper electrical connection.
C
B
A
A. Line 1
B. Ground-link
C. Hex washer head screw
D. Silver-colored terminal
block screw
3.
Connect the other 2 wires (lines 1 and 2)
to the outer terminal screws on the termi-
nal block.
4.
Tighten strain relief screws.
5.
Replace terminal block cover.
6.
Plug in range or reconnect power.
2-10
D
E
F
G
E. Neutral (center) wire
F. Line 2
G. UL listed strain relief
and 40 amp range power
supply cord

Hide quick links:

Advertisement

Table of Contents
loading