Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
DUAL BROIL ELEMENT
Outer Element
Inner Element
Refer to page 4-11 for the procedure for servic-
ing the dual broil element.
1.
Unplug range or disconnect power.
2.
Disconnect one of the wires from the inner
and outer dual broil element terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
inner broil element terminals. The meter
should indicate between 25 and 37 Ω.
5.
Touch the ohmmeter test leads to the
outer broil element terminals. The meter
should indicate between 32 and 44 Ω.
WARNING
Electrical Shock Hazard
CONVECTION ELEMENT
Refer to page 4-13 for the procedure for servic-
ing the convection element.
1.
Unplug range or disconnect power.
2.
Disconnect one of the wires from the con-
vection element terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
convection element terminals. The meter
should indicate between 29 and 41 Ω.
5-5