KitchenAid KESI901PBL Technical Education page 19

Self-cleaning slide - in/freestanding electric ranges
Table of Contents

Advertisement

Power Supply Cord Installation
WARNING: Improper connection of the equip-
ment-grounding conductor can result in a risk
of electric shock. Check with a qualified electri-
cian or service technician if you are in doubt as
to whether the appliance is properly grounded.
Do not modify the power supply cord plug. If it
will not fit the outlet, have a proper outlet
installed by a qualified electrician.
This range is manufactured with the neutral
terminal connected to the cabinet. Use a 3-
wire, UL listed, 40 amp power supply cord
(pigtail); or if local codes do not permit ground
through the neutral, use a 4-wire power supply
cord rated at 250-volts, 40 amps and investi-
gated for use with ranges.
1.
Remove the knockout for the 40 amp
power supply cord.
A
A. Remove knockout for 40 amp power cord
and UL listed strain relief
2.
Assemble a UL listed strain relief in the
opening.
3.
Feed the power supply cord behind the
black horizontal crossbrace and through
the strain relief, allowing enough slack to
easily attach the wiring to the terminal
block.
A. Black horizontal cross brace
B. Power supply cord
4.
5.
4-wire connection: Power supply cord
Use this method for:
• New branch-circuit installations (1996 NEC)
• Mobile homes
• Recreational vehicles
• In an area where local codes prohibit ground-
1.
2.
A
B
2-9
Connect the terminals (ring-type or spade
with upturned ends) on the end of the
power cord to the power supply.
Complete electrical connection according
to your type electrical supply (4-wire or
3-wire electrical connection).
ing through the neutral
Remove the ground-link screw from the
range frame. Save the ground link screw
and cup washer. Bend the ground-link
away from the range so that it does not
contact the range.
B
A
A. Ground-link screw
B. Cup washer
C. Ground-link bent away from range
Connect the green ground wire from the
power supply cord to the range using the
ground-link screw and cup washer. The
ground wire must be attached first and
must not contact any other terminal.
C