DIAGNOSTICS & TROUBLESHOOTING
#1 Oven Temp
Sensor Readout
* If available (3 dashes will be shown if not available)
ENTERING MANUAL DIAGNOSTICS
Within 120 seconds of power up, press the following keys to enable the relay capabilities listed
below, and enter the manual diagnostics mode:
a) Cancel key.
b) Cancel key.
c) Start key.
ENGAGING THE RELAYS
Pressing the following keys will toggle the state of the associated relays. NOTE: For the latch relay,
the self-clean button will turn on the latch relay, and changing the state of the latch switch will turn
off the relay.
Key Press
Bake Key
Maxi Broil Key
Econo Broil Key
Convect Bake
Warm Drawer On Warm Drawer Relay
Top Light
Oven Light
Clean Key
DOUBLE LINE BREAK (DLB), FANS, AND OPEN DOOR
During diagnostics, all fans and elements may operate with the door open. NOTE: The latch motor
will not cycle with the door open.
On electric models, the double line break (DLB) will engage when entering the diagnostics mode,
and will disengage when exiting the diagnostics mode.

DIAGNOSTICS

Relay Being
Engaged
O . BROIL REL CYCLED
0
72
F
AM34 UI30
Version
Relay
Bake Relay
Outer Broil Relay
Inner Broil Relay
Conv Relay and Fan
Oven Light Relay
Top Light Relay
Cycle Motor
After Latch Sw Toggles
Door
Latch
Meat Probe
Switch
Readout*
Switch
0
73
EEKET - 002
#2 Oven Temp
Sensor Readout*
Text Line Display
BAKE RELAY CYCLED
O.BROIL REL CYCLED
I.BROIL REL CYCLED
CONV REL CYCLED
WD RELAY CYCLED
O LIGHT REL CYCLED
T LIGHT REL CYCLED
ROTATING MOTOR
MOTOR ROTATED
6-1
F
E
Code
Code
73
Warming Drawer
Sensor Readout*