LeCroy CrossSync User Manual

Protocol analyzers

Advertisement

Quick Links

CrossSync User Manual
For
LeCroy Protocol Analyzers
CrossSync Control Panel Version 2.21
Document Version 1.12
August 2011

Advertisement

Table of Contents
loading

Summary of Contents for LeCroy CrossSync

  • Page 1 CrossSync User Manual LeCroy Protocol Analyzers CrossSync Control Panel Version 2.21 Document Version 1.12 August 2011...
  • Page 2 LeCroy Protocol Solutions Group  Copyright © 2011 LeCroy Protocol Solutions Group. All rights reserved.  Trademarks and Servicemarks: LeCroy, LeCroy Protocol Solutions Group, CATC, SASSuite, SATASuite, SASTracer, SATracer, SASTrainer, SATrainer, SASTracker  are trademarks of LeCroy.  Microsoft, Windows, Windows 2000, and Windows XP are registered trademarks of Microsoft  Inc.  Intel and Pentium are registered trademarks of Intel Corporation. All other trademarks and registered trademarks are property of their respective owners. THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE  WITHOUT NOTICE. ALL INFORMATION, EXAMPLES AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE  ACCURATE BUT ARE REPRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS ARE FULLY  RESPONSIBLE FOR THEIR APPLICATION OF ANY PRODUCTS. THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN  INFORMATION THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE  UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT LeCroy FOR A COPY. Copyright © 2011, LeCroy Corporation; All rights reserved. This document may be printed and reproduced without additional permission, but all copies should contain this copyright  notice. LeCroy Corporation 3385 Scott Blvd. Santa Clara, CA 95054 TEL: 800-909-7112 (USA and Canada) TEL: 408-653-1260 (worldwide) CrossSync User Manual...
  • Page 3: Table Of Contents

    (ACC-EXP-002-X) ..........................10 Connecting Three Analyzers with Built-in Micro-D Sync Ports ..............11 Connecting Three Analyzers with DB-9 Sync Ports...................12 Connecting Kibra 380 DDR3 Protocol Analyzer for CrossSync with the IOTA Software Suite....13 Chapter 3: Software ....................15 CrossSync Software Overview....................15 CrossSync Control Panel......................16 Launching the Application ...........................16...
  • Page 4 Trace File Tab ............................18 Time Tune Tab .............................19 General Tab ............................19 Dockable Bar ............................20 System Tray ............................20 Main Buttons ............................21 Session Configuration ..........................23 Topology View .............................24 CrossSync Synchronized Time Stamps ................... 25 Appendix A: How to Contact LeCroy ..............27 Index:........................29 CrossSync User Manual...
  • Page 5: Chapter 1: Introduction

    Chapter 1 Introduction The LeCroy CrossSync control panel provides synchronization for complete end‐to‐end  visibility into multi‐protocol systems.  This document discusses the overview, hardware setup and software for the CrossSync  Multi‐Protocol analysis system. CrossSync Multi-Protocol Analysis option CrossSync is LeCroy’s analyzer synchronization solution that enables time‐aligned display  of protocol traffic from multiple daisy‐chained analyzers showing packet traffic from  multiple high‐speed serial busses. A lightweight software control panel allows users to  select analyzers for synchronization and manage the recording process. Captured traffic is  displayed using the latest analyzer software (in separate windows) with all the protocol  specific search and reporting features. Captured packets are displayed in separate windows that share a common time scale.  Navigating the traffic in either direction will scroll to the same timestamp in a  synchronized window. When using the CrossSync option, users can access the full  complement of analysis capabilities available within the individual LeCroy software.  Search, reporting, and decoding all operate normally. The CrossSync option supports a wide combination of LeCroy's flagship analyzers  including PCI Express Gen 1, Gen 2, and Gen 3; USB 2.0 and 3.0; Serial ATA (SATA) 1.5, 3,  and 6Gbps; Serial Attached SCSI (SAS) 3 and 6Gbps; Fibre Channel 1, 2, 4, and 8 Gbps  systems and DDR3.  CrossSync User Manual...
  • Page 6: Crosssync-Capable Products

    LeCroy Corporation CrossSync‐Capable Products CrossSync-Capable Products The following products support CrossSync operation: TABLE 1.1: LeCroy Protocol Suites and Products Required Software Product USB Protocol Suite 4.20 and later USB Voyager M3i USB Advisor T3 SAS/SATA Protocol Suite 4.00 and later SAS/SATA Sierra M6‐4 SAS/SATA Sierra M6‐2 SAS/SATA Sierra M6‐1 FC Protocol Suite 3.25 and later SierraFC M8‐4 PETracer 6.50 and later PCIe Summit T28 PCIe Summit T3‐16 PCIe Summit T3‐8 DDR Protocol Suite 1.01 Kibra 380 DDR3  IOTA Software Suite 1.00 LeCroy will add support for more protocol analysis products in the future. Overview of the CrossSync Hardware The CrossSync capability requires that analyzers are connected using their Sync ports.  CrossSync can be used with the built‐in Sync port included on every Advisor T3 and Sierra  M6‐1 analyzer. For owners of LeCroy’s Sierra, Summit T3, and Voyager M3i based ...
  • Page 7: Chapter 2: Hardware Setup

    Chapter 2 Hardware Setup CrossSync Hardware Requirements The CrossSync capability requires that analyzers are connected using their Sync ports.  CrossSync can be used with the built‐in Sync port included on every Advisor T3 and Sierra  M6‐1 analyzer. For owners of LeCroy’s Sierra, Summit T3, and Voyager M3i based  analyzers, the CATC Sync port requires the optional expansion board (ACC‐EXP‐002‐X). Up  to eight analyzers may be connected in a single chain. The AdvisorT3 and Sierra M6‐1 use the built‐in Micro‐D Sync port and only require the  Micro‐D Sync cable (AC031XXA‐X). Systems with an expansion slot (such as Sierra M6‐4, Sierra M6‐2, SierraFC M8‐4, Voyager  M3i, and Summit T3‐16) require the CATC Sync Expansion Card and DB‐9 Sync cable (ACC‐ EXP‐002‐X). The Kibra 380 DDR3 and PCIe Summit T28 use built‐in DB‐9 sync ports and require a DB‐9  sync cable (ACC‐EXP‐002‐X). Analyzers daisy‐chained via sync cables will automatically synchronize time stamps,  trigger, recording start, and recording stop.  CrossSync User Manual...
  • Page 8 LeCroy Corporation CrossSync Hardware Requirements TABLE 2.2: LeCroy Analyzers and Cables Required for CrossSync Option Analyzers and Cables Product Analyzers with built‐in Micro‐D Sync  USB Advisor T3 Ports requiring Micro‐D Sync cable SAS/SATA Sierra M6‐1 (AC031XXA‐X) Analyzers requiring CATC Sync SierraFC M8‐4 Expansion Cards and DB‐9 Sync cable SAS/SATA Sierra M6‐4 (ACC‐EXP‐002‐X) SAS/SATA Sierra M6‐2 PCIe Summit T3‐16 PCIe Summit T3‐8 USB Voyager M3i Analyzers with built‐in DB‐9 Sync ports  Kibra 380 DDR3 requiring DB‐9 sync cable  PCIe Summit T28 (ACC‐EXP‐002‐X) Required Cables DB‐9 Sync cable (ACC‐EXP‐002‐X) CrossSync User Manual...
  • Page 9 CrossSync Hardware Requirements  LeCroy Corporation TABLE 2.2: LeCroy Analyzers and Cables Required for CrossSync Option Analyzers and Cables Product Micro‐D Sync cable (AC031XXA‐X) Micro‐D to DB‐9 Sync cable (AC030XXA‐X)   CrossSync User Manual...
  • Page 10: Host Pc Connections Using Various Configurations

    LeCroy Corporation Host PC Connections Using Various Configurations Host PC Connections Using Various Configurations An analyzer connected in a CrossSync configuration may be connected to the Host PC  using any host interface connection supported by the analyzer.  The CrossSync control panel running on the Host PC can then be used to control all  synchronized analyzers for time‐synchronized recording sessions. CrossSync Cabling for Various Configurations Connecting a Sierra M6-1 SAS/SATA Analyzer and a Advisor T3 USB Analyzer via the Micro-D Sync Cable The devices are connected using their built‐in Sync ports. Perform the following steps: 1. Make sure to stop any recordings in progress. Note: You may plug/unplug the sync cable while the analyzer unit is powered on. 2. Connect the Advisor T3 to the Sierra M6‐1 using the built‐in Sync ports via the ...
  • Page 11: Connecting Two Voyager M3I Usb Analyzers Via The Catc Sync Expansion Card (Acc-Exp-002-X)

    Host PC Connections Using Various Configurations  LeCroy Corporation Connecting Two Voyager M3i USB Analyzers via the CATC Sync Expansion Card (ACC-EXP-002-X) Two Voyager M3i USB analyzers are connected using their CATC Sync ports which require  an optional expansion board (ACC‐EXP‐002‐X).  Note: Refer to relevant protocol analyzer user manual for instructions on how to install the expansion  board. To do so perform the following steps: 1. Make sure to stop any recordings in progress. Note: You may plug/unplug the sync cable while the analyzer unit is powered on. 2. Connect the female end of the sync cable to the SYNC OUT port of the first analyzer. 3. Connect the male end of the sync cable to the SYNC IN port of the second analyzer. Figure 2.2: Two Voyager M3i Analyzers Daisy-chained   CrossSync User Manual...
  • Page 12: Connecting An Advisor T3 And A Sierra M6-2

    LeCroy Corporation Host PC Connections Using Various Configurations Connecting an Advisor T3 and a Sierra M6-2 This configuration requires the optional Micro‐D to DB‐9 sync cable (AC030XXA‐X). To do so perform the following steps: 1. Make sure to stop any recordings in progress. Note: You may plug/unplug the sync cable while the analyzer unit is powered on. 2. Connect the Micro‐D end of the sync cable to the Sync/Data port of the Advisor T3. 3. Connect the male end of the DB‐9 cable to the SYNC IN port of the Sierra M6‐2.  (Alternatively, connect the female end of the DB‐9 cable to the SYNC OUT port of  the Sierra M6‐2.) Figure 2.3: Connecting an Advisor T3 and a Sierra M6-2 Analyzers CrossSync User Manual...
  • Page 13: Connecting An Advisor T3, A Voyager M3I And A Summit T3-16

     LeCroy Corporation Connecting an Advisor T3, a Voyager M3i and a Summit T3-16 This configuration requires the optional Micro‐D to DB‐9 sync cable (AC030XXA‐X). This example shows connecting an Advisor T3, a Voyager M3i USB and a PCIe Summit T3‐ 16 analyzer. To do so perform the following steps: 1. Make sure to stop any recordings in progress. Note: You may plug/unplug the sync cable while the analyzer unit is powered on. 2. Connect the Micro‐D end of the sync cable to the Sync/Data port of the Advisor T3. 3. Connect the male end of the DB‐9 cable to the SYNC IN port of the Voyager M3i. 4. Connect the female end of the DB‐9 cable to the SYNC OUT port of the Summit T3‐ Figure 2.4: Daisy-chaining an Advisor T3, a Voyager M3i and a Summit T3-16   CrossSync User Manual...
  • Page 14: Connecting A Sierrafc M8-4 And A Summit T3-16 Via The Catc Sync Expansion Card (Acc-Exp-002-X)

    Connecting a SierraFC M8-4 and a Summit T3-16 via the CATC Sync Expansion Card (ACC-EXP-002-X) A SierraFC M8‐4 and a PCIe Summit T3‐16 are connected using their CATC Sync ports  which require an optional expansion card (ACC‐EXP‐002‐X). Note: Refer to relevant protocol analyzer user manual for instructions on how to install the expansion  board. To do so perform the following steps: 1. Make sure to stop any recordings in progress. Note: You may plug/unplug the sync cable while the analyzer unit is powered on. 2. Connect the female end of the sync cable to the SYNC OUT port of the SierraFC  M8‐4. 3. Connect the male end of the sync cable to the SYNC IN port of the PCIe Summit  T3‐16. Figure 2.5: Connecting a SierraFC M8-4 and a Summit T3-16 CrossSync User Manual...
  • Page 15: Connecting Three Analyzers With Built-In Micro-D Sync Ports

    Host PC Connections Using Various Configurations  LeCroy Corporation Connecting Three Analyzers with Built-in Micro-D Sync Ports The following example shows how to daisy‐chain 3 analyzers with built‐in Micro‐D sync  ports. To do so perform the following steps: This configuration requires the optional Micro‐D to DB‐9 sync cable (AC030XXA‐X). 1. Make sure to stop any recordings in progress. Note: You may plug/unplug the sync cable while the analyzer unit is powered on. 2. Connect the analyzers using the built‐in on‐board Sync/Data ports. 3. Connect the Micro‐D end of the sync cable to the Sync/Data port of the first  analyzer. 4. Connect the male end of the DB‐9 cable to the female end of the second DB‐9 cable. 5. Connect the Micro‐D end of the sync cable to the Sync/Data port of the second  analyzer. 6. Connect the male end of the DB‐9 cable to the female end of the third DB‐9 cable. 7. Connect the Micro‐D end of the sync cable to the Sync/Data port of the third  analyzer. Figure 2.6: Connecting Three Analyzers   CrossSync User Manual...
  • Page 16: Connecting Three Analyzers With Db-9 Sync Ports

    LeCroy Corporation Host PC Connections Using Various Configurations Connecting Three Analyzers with DB-9 Sync Ports The following example shows how to daisy‐chain 3 analyzers with DB‐9 sync ports. To do  so perform the following steps: This configuration requires two DB‐9 sync cable. 1. Make sure to stop any recordings in progress. Note: You may plug/unplug the sync cable while the analyzer unit is powered on. 2. Connect the female end of the first sync cable to the SYNC OUT port of the first  analyzer. 3. Connect the male end of the first sync cable to the SYNC IN port of the second  analyzer. 4. Connect the female end of the second sync cable to the SYNC OUT port of the  second analyzer. 5. Connect the male end of the second sync cable to the SYNC IN port of the third  analyzer. CrossSync User Manual...
  • Page 17: Connecting Kibra 380 Ddr3 Protocol Analyzer For Crosssync With The Iota Software Suite

    Host PC Connections Using Various Configurations  LeCroy Corporation Connecting Kibra 380 DDR3 Protocol Analyzer for CrossSync with the IOTA Software Suite Kibra 380 usage with IOTA requires the Ref Clk In, Trigger In and Trigger Out SMAs (see  Figure 2.7). Figure 2.7: Kibra Rear Panel Connections See the LeCroy IOTA Software Suite User Manual for details.   CrossSync User Manual...
  • Page 18 LeCroy Corporation Host PC Connections Using Various Configurations CrossSync User Manual...
  • Page 19: Chapter 3: Software

    Chapter 3 Software CrossSync Software Overview The CrossSync control panel does not have a separate installer and instead is embedded in  the Protocol Suite installers. The solution includes a lightweight software control panel that starts and stops recording  across daisy‐chained analyzers. Users can sync or un‐sync traces on‐the‐fly. The Time Tune  feature provides a real‐time slider for adjusting the off‐set between displays. This makes it  easy to see latency across busses.  Start and Stop Synchronized Recordings Use the Time Tune slider to adjust the  off‐set between displays Open previously captured traces which  Easily Discover and Sync Analyzers attached to the system remain synchronized Un‐sync traces to scroll each window separately Figure 3.1: CrossSync Control Panel The CrossSync control panel requires the analyzers to be connected using their Sync ports.  This Sync port is built‐in to every Advisor T3 and Sierra M6‐1 analyzer. For owners of  LeCroy’s Summit T3, Voyager M3i, and Sierra ‐based analyzers, the Sync port is available as  an optional expansion board (ACC‐EXP‐002‐X) that can be installed by users in just a few  minutes. This allows developers to leverage analyzers already in the lab to help resolve  multi‐protocol problems at the system level.  CrossSync User Manual...
  • Page 20: Crosssync Control Panel

    LeCroy Corporation CrossSync Control Panel CrossSync Control Panel Launching the Application Click Start > Programs > LeCroy > CrossSync > CrossSync Control Panel to launch the  application. On first launching the CrossSync Control Panel, the LeCroy CrossSync Settings  dialog is displayed. The Settings dialog displays all the available Protocol Applications  Suites. Select the protocol applications you want to use and click OK. The selected  applications are launched automatically.   Figure 3.2: LeCroy CrossSync Settings Dialog Applications Tab The Applications tab displays all the available applications. On subsequent sessions, your  preferred applications are automatically launched. You may change the applications at  any time from the Settings dialog. CrossSync User Manual...
  • Page 21: Application Overview

    CrossSync Control Panel  LeCroy Corporation Application Overview The following section introduces you to the application. Once the application launches, four tabs are displayed. They are explained below. Note: The Applications tab is explained in the previous section. Run Sequence Tab The Run Sequence tab is only used when using the LeCroy IOTA Software Suite. It displays  all the applications that are running. The IOTA start capture is not hardware synced with  other analyzers. If other analyzers will be the trigger source, then move IOTA to the top of  the list. If IOTA will be the trigger source, then move IOTA to the bottom of the list. You  can move IOTA up and down as follows: 1. Select IOTA Protocol Suite in the Sequence of Run pane  2. Click Move Up or Move Down as required. Figure 3.3: Run Sequence Tab   CrossSync User Manual...
  • Page 22: Trace File Tab

    LeCroy Corporation CrossSync Control Panel Trace File Tab The Trace File tab displays the Output Trace File(s) Path. Click the Browse (“...”) button to  select a new path. Check the box if you want to save each run in a new folder. New folders  are assigned names based on the recording session start date and time.  Figure 3.4: Trace File Tab Note: The default trace file location on Windows XP is  C:\Program Files\Common Files\LeCroy Shared\Traces.  The default trace file location on Windows Vista and Windows 7 is  C:\Users\Public\Documents\LeCroy\CrossSync\Traces. CrossSync User Manual...
  • Page 23: Time Tune Tab

    CrossSync Control Panel  LeCroy Corporation Time Tune Tab The Time Tune tab provides an interactive slider for adjusting the offset between displays.  The Source is the time reference point for the Target. The Target time‐sync is offset by  Delta relative to the Source. The Time Tune tab displays the following: Source ‐ Double‐click on the icon to switch the Source.  Target ‐ Displays the target.  Delta ‐ Enter a value or slide the tuner to select the offset.  Time Type ‐ Select a value in seconds, milliseconds, microseconds or nanosec‐  onds from the drop‐down list. Figure 3.5: Time Tune Tab General Tab The General tab allows you set the general settings. Select the check‐box to show the  information balloon popups in the Windows System Notification Tray. Figure 3.6: General Tab   CrossSync User Manual...
  • Page 24: Dockable Bar

    LeCroy Corporation CrossSync Control Panel Dockable Bar By default, the application will dock to the top of the screen. Right‐click in the bar to  invoke a context menu that allows to change the docking orientation or to make it a  floating window. You can select AutoHide to hide the tool bar; when you move the mouse  cursor to the top of the screen, the tool bar will re‐appear. Figure 3.7: Dockable Bar System Tray The application automatically installs a LeCroy CrossSync Control Panel System Tray icon  for easy access. Figure 3.8: System Tray Icon Right‐click on the System Tray icon for quick access to the control panel functions. The  options on the menu will be displayed according to the applications being used. Figure 3.9: System Tray Icon Functions CrossSync User Manual...
  • Page 25: Main Buttons

    CrossSync Control Panel  LeCroy Corporation Main Buttons The main icons are explained in the following table. TABLE 3.3: Main Icons and Descriptions Icons Descriptions and Submenus Open File The Open File icon opens a set of synchronized traces from a  previous session. This is a dual‐mode button; clicking on the down  arrow displays the following menu: Zip Most Recent Traces  Open Traces Folder in Windows Explorer  Break Sync.  The Break Sync. Trace Files icon toggles the view synchronization  Trace Files between traces. Select  The Select Application icon allows you to select the application suite  Application you would like to run. This is a dual‐mode button; clicking on the  down arrow displays the following menu: FC Protocol Suite  PETracer  SAS Protocol Suite  SATA Protocol Suite ...
  • Page 26 LeCroy Corporation CrossSync Control Panel Stop The Stop icon stops a session.  Applications  Clicking the Applications Layout icon re‐applies the last selected  Layout layout. This is a dual‐mode button; clicking on the down arrow  displays the following menu: Horizontal  Displays the application windows horizontally. Cascading  windows are displayed if more than one application is open.  Vertical  Displays the application windows vertically. Windows are  displayed cascading vertically, if more than one application is  open.  Custom Layout  Displays a custom application layout.  Multimonitor  Displays the application windows across dual monitors.  Save Current layout  Saves the current application layout display. Help The Help icon opens the Help and About dialog. This is a dual‐mode  button; clicking on the down arrow displays the following menu: Help  About  Close The Close icon closes the application and all protocol applications.  CrossSync User Manual...
  • Page 27: Session Configuration

    CrossSync Control Panel  LeCroy Corporation Session Configuration The Device List allows for easy discovery and selection of analyzers for synchronization  (see the table below).  Perform the following steps to configure a session: 1. Open the Devices dialog and select the devices you want to use by checking the  corresponding boxes in the Set column of the list. Figure 3.10: Devices Dialog 2. For each selected device, click the Record Setting icon   to invoke the settings  dialog for that device in its respective protocol application. See the protocol  application’s User Manual for details on how to configure the settings. 3. Click Close to close the Devices dialog.   CrossSync User Manual...
  • Page 28: Topology View

    LeCroy Corporation CrossSync Control Panel TABLE 3.4: CrossSync Devices: Device List Tab Column Descriptions Columns Description Item number Numeric list of device. Sel. Device Selection checkbox. Check the box to include  the device in the recording session. Uncheck the box  to exclude the device from the recording session. Device Device Name and Serial Number. Protocol Suite Icon of the Protocol Suite of the device being used is  displayed. Record Setting Click to invoke the settings dialog for that device in  its respective protocol application. Location Location of the device (local or on the network) Ports Identifies ports P1, P2, P3, and P4. A   icon  indicates an Analyzer is connected. A   icon  indicates the port is not being used.  Status Indicates the status of the device. They are: Ready ‐ Device is ready to begin a session. Working ‐ Device is currently in a session. Ready to connect ‐ Device is on the network and ...
  • Page 29: Crosssync Synchronized Time Stamps

    CrossSync Synchronized Time Stamps  LeCroy Corporation CrossSync Synchronized Time Stamps Synchronized time stamps make it easy to find the precise point where events from one  bus cross over an adjacent protocol bridge as shown below. Clicking on a packet in one  view will cause the other view to jump to the corresponding time point (taking into  account the Time‐Tune settings). Figure 3.12: Synchronized Time Stamps Using the CrossSync Control Panel you can use triggering to find the same packet traveling  across both busses, identifying the point where a specific bus event moves over a bridge.  Either analyzer can be setup as the trigger master. When the trigger event is detected, the  capture stops and the display shows the exact point where the event occurred. Separate  trigger events that operate independently for each side of the bridge can also be defined.   CrossSync User Manual...
  • Page 30 LeCroy Corporation CrossSync Synchronized Time Stamps CrossSync User Manual...
  • Page 31: Appendix A: How To Contact Lecroy

    Appendix A How to Contact LeCroy Type of Service Contact Call for technical support… US and Canada: 1 (800) 909‐7112 Worldwide: 1 (408) 653‐1260 Fax your questions… Worldwide: 1 (408) 727‐6622 Write a letter… LeCroy Protocol Solutions Group Customer Support 3385 Scott Blvd. Santa Clara, CA 95054‐3115 Send e‐mail… psgsupport@lecroy.com Visit LeCroy’s web site… http://www.lecroy.com/  CrossSync User Manual...
  • Page 32 LeCroy Corporation CrossSync User Manual...
  • Page 33: Index

    Host PC Connections Using Various Configurations Advisor T3 and a Sierra M6-2 8 Advisor T3, a Voyager M3i and a Summit T3-16 9 Kibra 380 DDR3 Protocol Analyzer for CrossSync with the IOTA Launching the Application Software Suite 13 Sierra M6-1 SAS/SATA Analyzer and a Advisor T3 USB Analyzer LeCroy Analyzers and Cables Required for ...
  • Page 34 LeCroy Corporation Index Select Application Select Application icon Session Configuration Settings Settings icon support System Tray System Tray Icon System Tray Icon Functions Technical Support telephone number Time Tune Tab Topology View Trace File Tab web site Website, CATC CrossSync User Manual...
  • Page 35 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Teledyne LeCroy AC031XXA-X AC030XXA-X...

Table of Contents