Configuring The Gira X1 Client; Initial Commissioning - Gira G1 Assembly And Operating Instructions Manual

Table of Contents

Advertisement

5

Configuring the Gira X1 Client

The following prerequisites must be fulfilled for commissioning to be successful:
-
The Gira X1 must be configured to be functional.
-
When configuring the Gira X1 in the Gira Project Assistant, a user must be
configured for the Gira G1.
-
The Gira G1, the Gira X1 and the commissioning PC (with Gira Project Assis-
tant installed) must be located on the same network.
5.1

Initial commissioning

Once you have selected the "Gira X1 and security system" option in the Gira
G1's basic configuration, the initial commissioning configuration starts up, fol-
lowed by a dialog that allows you to make the connection to the Gira X1.
1 If the Gira G1 is connected to the network via LAN and DHCP, you can pro-
ceed directly to step 2.
If the Gira G1 is connected to the network via WLAN and/or without DHCP,
you must first connect to the network before you can connect to the Gira X1.
2 Enter the connection data (user name and password), which you created ear-
lier for the Gira G1 in the GPA [see 6.1.2.1].
3 Enter the access data for the door communication system, if appropriate
[see 15.2.1].
4 Select the locations for the weather station, as appropriate [see 17.1.1].
Note
Maximum number of functions to be configured
Please note that out of the 250 permitted functions, you may use a maximum of
60 dimming or temperature functions (with adjustable scale).
Gira G1
Figure 36