3. Removal of Electrical Box

Procedure
Step
1. Layout of the parts
2. Remove the drip proof
plate.
Remove the screw.
1
2
Remove the drip proof
plate from the indoor
heat exchanger.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Drip proof plate
Removal of Electrical Box
Preparation
Remove the front grille
according to the "Removal of
Front Grille."
1 2
3
(R16270)
3
1 2
(R16271)
When reassembling, fit the
hook to the indoor heat
exchanger.
(R16272)
Points
(R16273)
7