Daikin FTKD24HV2S Service Manual page 31

5.0/6.0/7.1 kw class 15000/18000/24000/28000 btu/h class removal procedure

Advertisement

Si041144
Step
Remove the piping
4
fixture.
3. Remove the indoor heat
exchanger.
1
Slightly widen the
auxiliary piping.
Remove the 2 screws
2
on the left side.
Removal Procedure
Procedure
Removal of Indoor Heat Exchanger
Points
(R9574)
(R9575)
Caution
When removing or
reassembling the indoor heat
exchanger, be sure to wear
gloves or wrap the indoor
heat exchanger with cloths.
(You may be injured by the
fins.)
(R13580)
29