Whirlpool WETLV27HW0 Service Manual page 23

27 inch gas & electric stacked laundry center
Table of Contents

Advertisement

Fault/Error Codes (Washer) Continued
FAULT/ERROR CODE - DESCRIPTION
Explanation & Recommended Procedure
(Status LED names may vary between makes and models)
F8E3 – OVERFLOW CONDITION
Fault is displayed when main control senses water level that exceeds the washer's capacity.
• May signify problem with inlet water valves.
• Check pressure hose connection from tub to pressure sensor. Is hose pinched, kinked, plugged, or leaking air?
• Onboard pressure transducer fault.
• Check for proper drain hose installation. Is water siphoning out of the drain hose? Drain hose must not be more than 4.5"
(114 mm) into the drain pipe. Make sure drain hose is not seated into drain pipe, and that there is an air gap for ventilation.
Ensure drain height is between 39" (991 mm) and 8' (2.4 m) above the floor.
• See TEST #2: Valves, page 3-7 and TEST #5: Water Level, page 3-13.
F8E5 – HOT, COLD REVERSED
Fault is displayed when the hot and cold inlet hoses are reversed.
• Make sure inlet hoses are connected correctly.
• See TEST #2: Valves, page 3-7.
F9E1 – LONG DRAIN
Fault is displayed when the water level does not change after the drain pump is on for 10 minutes.
• Is the drain hose or the drain pump clogged? Check tub sump under impeller for obstructions.
• Is the drain hose height greater than 8' (2.4 m)?
• Too much detergent.
• Check pressure hose connection from tub to pressure sensor. Is hose pinched, kinked, plugged, or leaking air?
• Is the pump running? If not, see TEST #6: Drain Pump, page 3-14.
For Service Technician Use Only
DIAGNOSTICS & TROUBLESHOOTING
FAULT NUMBER
Status LEDs
F
8
F
8
F
8
1
27" Stacked Laundry Center
ERROR NUMBER
Status LEDs
E
2
1
E
4
1
E
1
2-9
n

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents