Parameter Descriptions
15-10 Logging Source
Array [4]
Option:
3
3
[1651] Pulse Reference
[1652] Feedback [Unit]
[1657] Feedback [RPM]
[1660] Digital Input
[1662] Analog Input 53
[1664] Analog Input 54
[1665] Analog Output 42 [mA]
[1666] Digital Output [bin]
[1675] Analog In X30/11
[1676] Analog In X30/12
[1677] Analog Out X30/8 [mA]
[1690] Alarm Word
[1692] Warning Word
[1694] Ext. Status Word
[1860] Digital Input 2
[3110] Bypass Status Word
[3470] MCO Alarm Word 1
[3471] MCO Alarm Word 2
15-11 Logging Interval
Range:
Application
dependent
*
15-12 Trigger Event
Select the trigger event. When the trigger event occurs, a window
is applied to freeze the log. The log will then retain a specified
percentage of samples before the occurrence of the trigger event
(15-14 Samples Before Trigger).
Option:
[0]
*
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
[14]
[15]
3-128
FC 300 Programming Guide
Function:
Function:
[Application
Enter the interval in
dependant]
milliseconds between each
sampling of the variables to
be logged.
FALSE
TRUE
Running
In range
On reference
Torque limit
Current limit
Out of current range
Below I low
Above I high
Out of speed range
Below speed low
Above speed high
Out of feedb. range
Below feedb. low
Above feedb. high
MG.33.MA.22 - VLT
15-12 Trigger Event
Select the trigger event. When the trigger event occurs, a window
is applied to freeze the log. The log will then retain a specified
percentage of samples before the occurrence of the trigger event
(15-14 Samples Before Trigger).
Option:
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[23]
[24]
[25]
[26]
[27]
[28]
[29]
[33]
[34]
[35]
[36]
[37]
[38]
[50]
[51]
[60]
[61]
15-13 Logging Mode
Option:
[0]
Log always
*
Function:
[1]
Log once on
trigger
15-14 Samples Before Trigger
Range:
50
[0 - 100 ] Enter the percentage of all samples prior to a
*
®
is a registered Danfoss trademark
Thermal warning
Mains out of range
Reverse
Warning
Alarm (trip)
Alarm (trip lock)
Comparator 0
Comparator 1
Comparator 2
Comparator 3
Logic rule 0
Logic rule 1
Logic rule 2
Logic rule 3
Digital input DI18
Digital input DI19
Digital input DI27
Digital input DI29
Digital input DI32
Digital input DI33
Comparator 4
Comparator 5
Logic rule 4
Logic rule 5
Function:
Select Log always [0] for continuous
logging.
Select Log once on trigger [1] to
conditionally start and stop logging using
15-12 Trigger Event and 15-14 Samples Before
Trigger.
Function:
trigger event which are to be retained in the log.
See also 15-12 Trigger Event and 15-13 Logging
Mode.
Function: