NO.
DESCRIPTION
1
300 psi/ 2000 kPa Water Pressure Gauge
2
1/4" Gauge Test Valve
. . . . . . . . . . . . . . . . .
3
Model MC-1 Manual Control Station
. . . . . .
4
Model AD-1 Automatic Drain Valve
. . . . . . .
5
Model ASV-1 Automatic Shut-Off Valve
35
35
1
7
20
3" (DN80)
2
GROOVE x GROOVE
DV-5 DELUGE VALVE
33
SHOWN
33
35
24
22
39
28
40
7
LOCATION
35
FOR OPTIONAL
ELECTRICALLY
SUPERVISED
N.O. ALARM
25
CONTROL
45
VALVE
21
30
36
A1
(ORDERED
SEPARATELY)
12
Step 9. Conduit and electrical connec-
tions are to be made in accordance
with the requirements of the authority
having jurisdiction and/or the National
Electric Code.
Step 10. Before a system hydrostatic
test is performed in accordance with
NFPA 13 system acceptance test re-
quirements, the DV-5 Diaphragm
Chamber is to be depressurized, the
Automatic Drain Valve (Item 4, Fig. 3A
and 5) is to be temporarily replaced
with a 1/2 inch NPT plug, the 3/32 inch
Vent Fitting (Item 16 - Fig. 3A and 5)
is to be temporarily replaced with a
1/4 inch NPT plug, and the Diaphragm
Cover Bolts must be uniformly and se-
curely tightened using a cross-draw
sequence. After tightening, double-
check to make certain that all of the
Diaphragm Cover Bolts are securely
tightened.
QTY.
P/N
NO.
DESCRIPTION
. .
2
92-343-1-005
6
Item No. Not Used
1
46-005-1-002
7
1/2" Ball Valve
1
52-289-2-001
8
1/2" Spring Loaded Check Valve
1
52-793-2-004
9
1/2" Y-Strainer
. . .
1
92-343-1-021
10
3/4" Swing Check Valve
35
35
25
22
9
8
5
37
25
35
22
35
38
35
30
23
10
44
28
44
16
(GREEN
48
TINT)
17
23
47
43
32
26
43
3 INCH (DN80) DV-5 DELUGE VALVE
EXPLODED VIEW OF HORIZONTAL ELECTRIC ACTUATION TRIM
QTY.
P/N
. . . . . . . . . . . . . . . . . . . . . . .
2
46-050-1-004
. . . . . . . . .
1
92-322-1-002
. . . . . . . . . . . . . . . . . . . . . . .
1
52-353-1-005
. . . . . . . . . . . . . . . .
1
46-049-1-005
E2
25
E4
E1
34
(ORDERED
SEPARATELY)
42
25
35
27
22
42
27
35
28
35
22
41
34
25
25
18
19
44
4
44
27
36
29
15
31
13
44
43
46
14
11
FIGURE 5 (2 OF 3)
NO.
DESCRIPTION
. . . . . . . . . . . . . . . . . . . . . .
11
3/4" Angle Valve
12
1-1/4" Angle Valve
. . . . . . . . . . . . . . . . . . . .
13
Drip Funnel Connector
. . . . . . . . . . . . . . . . .
14
Drip Funnel Bracket
. . . . . . . . . . . . . . . . . . .
15
Drip Funnel
. . . . . . . . . . . . . . . . . . . . . . . . . .
16
3/32" Vent Fitting
. . . . . . . . . . . . . . . . . . . . .
17
1/4" x 18" Tubing
. . . . . . . . . . . . . . . . . . . . .
18
1/2" Tubing Connector
. . . . . . . . . . . . . . . . .
19
1/2" x 12" Tubing
. . . . . . . . . . . . . . . . . . . . .
20
1/4" Plug
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
21
3/4" Plug
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
E3
22
1/2" Union
. . . . . . . . . . . . . . . . . . . . . . . . . . .
23
3/4" Union
. . . . . . . . . . . . . . . . . . . . . . . . . . .
24
1/4" 90° Elbow
. . . . . . . . . . . . . . . . . . . . . . .
25
1/2" 90° Elbow
. . . . . . . . . . . . . . . . . . . . . . .
26
3/4" 90° Elbow
. . . . . . . . . . . . . . . . . . . . . . .
27
1/2" Tee
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
28
1/2" x 1/4" x 1/2" Tee
. . . . . . . . . . . . . . . . . .
29
3/4" Tee
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
30
3/4" x 1/2" x 3/4" Tee
. . . . . . . . . . . . . . . . . .
31
3/4" x 3/4" x 1/2" Tee
. . . . . . . . . . . . . . . . . .
32
1-1/4" x 3/4" x 1-1/4" Tee
. . . . . . . . . . . . . . .
33
1/4" x Close Nipple
. . . . . . . . . . . . . . . . . . . .
34
1/2" x Close Nipple
. . . . . . . . . . . . . . . . . . . .
35
1/2" x 1-1/2" Nipple
. . . . . . . . . . . . . . . . . . . .
36
1/2" x 2-1/2" Nipple
. . . . . . . . . . . . . . . . . . . .
37
1/2" x 3-1/2" Nipple
. . . . . . . . . . . . . . . . . . . .
38
1/2" x 4" Nipple
. . . . . . . . . . . . . . . . . . . . . . .
39
1/2" x 4-1/2" Nipple
. . . . . . . . . . . . . . . . . . . .
40
1/2" x 5" Nipple
. . . . . . . . . . . . . . . . . . . . . . .
41
1/2" x 5-1/2" Nipple
. . . . . . . . . . . . . . . . . . . .
3
42
1/2" x 7" Nipple
. . . . . . . . . . . . . . . . . . . . . . .
43
3/4" x Close Nipple
. . . . . . . . . . . . . . . . . . . .
44
3/4" x 1-1/2" Nipple
. . . . . . . . . . . . . . . . . . . .
45
3/4" x 2" Nipple
. . . . . . . . . . . . . . . . . . . . . . .
46
3/4" x 4-1/2" Nipple
. . . . . . . . . . . . . . . . . . . .
47
1-1/4" x 2" Nipple
. . . . . . . . . . . . . . . . . . . . .
48
1-1/4" x 4" Nipple
. . . . . . . . . . . . . . . . . . . . .
E1
Solenoid Valve Ordered Separately
Per Data Sheet TFP2180
. . . . . . . . . . . . . . .
E2
1/2" Tubing Connector
. . . . . . . . . . . . . . . . .
E3
1/2" x 24" Tubing
. . . . . . . . . . . . . . . . . . . . .
E4
1/2" x 1-1/2" Nipple
. . . . . . . . . . . . . . . . . . . .
COMPONENTS ORDERED SEPARATELY:
A1
Water ow Pressure Alarm Switch,
Model PS10-2
. . . . . . . . . . . . . . . . . . . . . . . .
NOTES:
1.
Electric Actuation Trim is comprised of
Items 1-48 plus Items E2-E4. Items A1
and E1 ordered separately.
2.
All Fittings and Nipples are galvanized
(Standard Order).
3.
CH: Common Hardware.
4.
See Figure 2 of TFP1305 for Valve Port
identi cation.
5.
Route all Tubing to Drip Funnel, Item 15.
6. Horizontal Arrangement uses only 7 out of
8 of Item 25, and 12 out of 13 of Item 35.
Discard unused material.
TFP1320
Page 11 of 14
QTY.
P/N
1
46-048-1-005
1
46-048-1-007
1
92-211-1-005
1
92-211-1-003
1
92-343-1-007
1
92-032-1-002
1
CH
1
CH
1
CH
1
CH
1
CH
5
CH
2
CH
1
CH
8
CH
1
CH
3
CH
3
CH
1
CH
2
CH
1
CH
1
CH
2
CH
2
CH
13
CH
2
CH
1
CH
1
CH
1
CH
1
CH
1
CH
2
CH
3
CH
5
CH
1
CH
1
CH
1
CH
1
CH
Refer to
1
Data Sheet
1
CH
1
CH
1
CH
1
25710