Edp Connector - Seco CCOMe-C30 User Manual

Carrier board for com-express type 6 module on 3.5 inch form factor
Table of Contents

Advertisement

3.3.14

eDP Connector

eDP connector
Pin
Signal
Pin
1
PTN_PWR
2
VDD_BKLT
3
VDD_BKLT
4
VDD_BKLT
5
VDD_BKLT
6
PTN_SMB_CLK
7
PTN_SMB_DAT
8
LVDS_BKLT_CTRL
9
LVDS_BKLT_EN
10
GND
11
GND
12
GND
13
GND
14
eDP_HPD
15
GND
16
GND
17
GND
18
GND
19
---
20
VDD_LVDS
JP13 position
External eDP-to-LVDS adapter
Inserted
Enabled
Not Inserted
Disabled
CCOMe-C30
CCOMe-C30 - Rev. First Edition: 1.0 - Last Edition: 1.0 - Author: S.B. - Reviewed by F.B. Copyright © 2019 SECO S.p.A.
CN33
Signal
21
VDD_LVDS
22
VDD_LVDS
23
VDD_LVDS
24
GND
25
eDP_AUX-
26
eDP_AUX+
27
GND
28
eDP_TX0+
29
eDP_TX0-
30
GND
31
eDP_TX1+
32
eDP_TX1-
33
GND
34
eDP_TX2+
35
eDP_TX2-
36
GND
37
eDP_TX3+
38
eDP_TX3-
39
GND
40
---
PTN_SMB_DAT: SM Bus control data line for external eDP-to-LVDS bridge adapter. Bidirectional signal,
electrical level PTN_PWR.
As mentioned in paragraph 3.3.12, the CCOMe-C30 carrier board is also able to manage eDP
Displays, when jumper JP10 is in position.
For the connection of this kind of displays, on-board there is a VESA
embedded Display Port interface, type STARCONN p/n 300E40-
0110RA-G3 or equivalent (microcoaxial cable connector, 0.5mm
pitch, 40 positions).
On this connector, VDD_BKLT and VDD_LVDS are the voltage rails that can be used to supply
the LCD and related Backlight Unit (please check par. 3.3.13)
Here following the signals involved in eDP management:
eDP_TX0+/eDP_TX0-: embedded DP differential data pair #0.
eDP_TX1+/eDP_TX1-: embedded DP differential data pair #1.
eDP_TX2+/eDP_TX2-: embedded DP differential data pair #2.
eDP_TX3+/eDP_TX3-: embedded DP differential data pair #3.
eDP_AUX+/eDP_AUX-: embedded DP auxiliary channel differential data pair.
eDP_HPD: embedded DP Hot Plug Detect. Active high signal.
LVDS_BKLT_EN: eDP Panel's Backlight Enable Signal. Please check par. 3.3.13 for a
description
LVDS_BKLT_CTRL: eDP Panel Backlight Brightness Control, PWM signal. Please check par.
3.3.13 for a description
PTN_PWR: 3.3V_S derived voltage for external eDP-to-LVDS bridge adapter. This power rail
will be enabled only in case jumper JP13 is placed, according to the table on the bottom of this
page
PTN_SMB_CLK: SM Bus control clock line for external eDP-to-LVDS bridge adapter. Output
signal, electrical level PTN_PWR.
®
certified connectors for
45