Gaskets - Larius Dragon Liner Operating And Maintenance Instruction Manual

Self-propelled line striper
Table of Contents

Advertisement

DRAGON LINER
Q
REPLACEMENT OF THE PUMPING GROUP'S GASKETS
Each time you use the machine, check for material leaking from
the top of the ring nut.
If any material leaks out when the pump is working at the set
pressure, proceed as follows:
Carry out this operation after cleaning the tooling.
Always disconnect the power supply and release
pressure before going on with the operations
(follow the "correct procedure of decompression).
The gaskets are self-adjusting. If a leak occurs
they must be replaced.
Disconnect the product feed hose (Q1) from the pump unit
by unscrewing the nut (Q2).
Unscrew the fixing ring nut (Q3) using the relevant closing
pin (Ref. 20144).
Q3
Ref. 20144
Release the plastic cover (Q4).
Q4
www.larius.eu
26
Pull the ignition belt (Q5) lightly until the piston rod has
been brought to the lowest point of its stroke.
Screw the appropriate supplied tool (Q6 – ref- 20213) into
the threaded hole on the holding pin (Q7).
Q7
Ref. 20213
Q2
Q6
Q1
Remove the pin (Q7) from its seating.
Q5
Q7
Ed. 002 - 01/2017