DRAGON LINER
PROBLEMS AND SOLUTIONS
O
Problem
Engine won't start
•
•
The equipment does not start
The equipment does not suck the
•
product
The equipment sucks but does
•
not reach the pressure desired
When pressing the trigger, the
•
pressure lowers considerably
•
The pressure is normal but the
product is not atomized
The atomization is imperfect
•
When releasing the trigger of
•
the gun, the equipment does not
stop (the motor runs slowly and
the piston rod keeps on going up
and down)
www.larius.eu
24
Cause
• The petrol manifold is closed;
• Engine is out of gas;
• Cold engine;
• Spark plug cable is disconnected or dama-
ged;
• On/Off switch disconnected;
• Breakdown of pressure transmitter;
• Breakdown of motor electric control box;
• The line of material coming out of the pump
is already under pressure;
• The product is solidified inside the pump;
• Suction filter clogged;
• Suction ilter too fine;
• The equipment sucks air;
• Lack of product;
• The equipment sucks air;
• The drain valve is open;
• The gaskets of the pumping group are worn;
• Suction or delivery valve dirty;
• Nozzle too big or worn;
• The product is too dense;
• The filter of the gun-butt is too fine;
• The nozzle is partially clogged;
• The product is too dense;
• The filter of the gun-butt is too fine;
• The nozzle is worn;
• The gaskets of the pumping group are worn;
• Suction or delivery valve dirty;
• Drain valve defective;
Solution
• Open the petrol manifold;
• Refill gas tank;
• Use choke;
• Connect spark plug cable or replace
spark plug;
• Ensure the On/Off switch is on the
"on" position and turn clockwise the
pressure control knob;
• Verify and replace it, if necessary;
• Verify and replace it, if necessary;
• Open the drain valve to release pres-
sure in the circuit;
• Open the drain valve to release
pressure in the circuit and stop the
machine. Disassemble the pumping
group and the pressure transmitter
and clean;
• Clean or replace it;
• Replace it with a larger-mesh filter (with
very dense products, remove the filter);
• Check the suction pipe;
• Add the product;
• Check the suction pipe;
• Close the drain valve;
• Replace the gaskets;
• Disassemble the pumping group;
• Replace it with a smaller one;
• Dilute the product, if possible;
• Replace it with a larger-mesh filter;
• Clean or replace it;
• Dilute the product, if possible;
• Replace it with a larger-mesh filter;
• Replace it;
• Replace the gaskets;
• Disassemble the pumping group and
clean;
• Verify and replace it, if necessary;
Ed. 002 - 01/2017