CORRECT PROCEDURE OF DECOMPRESSION
P
Move the switch (P1) to the OFF (0) position to stop the
•
equipment.
P1
•
Unlock the safety clamp (P2).
P2
•
Point the gun (P3) at the receptacle (P4) used to collect
the product and press the trigger to release the pressure.
When completed, activate the safety catch again.
Ed. 002 - 01/2017
ON
Clamp released
P4
•
Open the discharge valve (P5) to release the remaining
pressure.
WARNING:
If the equipment is still under pressure after perfor-
ming the operations above described because of
the nozzle or the flexible hose clogged, proceed
as follows:
•
Loosen very slowly the gun nozzle.
•
Release the clamp.
•
Point the gun at the container of the product
and press the trigger to release pressure.
•
Loosen very slowly the fitting of connection
from the flexible hose to the gun.
•
Clean or replace the flexible hose and the
nozzle.
DRAGON LINER
P3
P5
www.larius.eu