11.14.3

F_FB_KTP_RNG

Inputs
Parameter
ID
E_STOP_EXT
ENABLE_EXT
ACTIVATE_ENABLE
MP1_E_STOP
MP1_ENABLE
MP2_E_STOP
MP2_ENABLE
Mobile Panels 2nd Generation
Operating Instructions, 09/2018, A5E33876626-AC
Data type
Description
Word
The connection box is uniquely identified by
the ID set on the connection box. The ID
must be unique throughout the plant and
must match the value of this parameter. The
value has the following meaning:
0 or > 254: Invalid box ID, emergency stop
and acknowledgment button are disabled.
1...254: Valid box ID, emergency stop and
acknowledgment button enabled depending
on the mode of the HMI device.
Bool
External information on the state of the
emergency stop button of another
F_FB_KTP_RNG with cascading.
Bool
External information on the state of the
acknowledgement button of another
F_FB_KTP_RNG with cascading.
Bool
This input allows the acknowledgement
button to be enabled and disabled.
Word
Information from the F_FB_KTP_Mobile on
the state of the emergency stop button of
HMI device 1
Word
Information from the F_FB_KTP_Mobile on
the state of the acknowledgment button of
HMI device 1
Word
Information from the F_FB_KTP_Mobile on
the state of the emergency stop button of
HMI device 2
Word
Information from the F_FB_KTP_Mobile on
the state of the acknowledgment button of
HMI device 2
Technical specifications
11.14 Mobile Panel 2nd Generation F-FBs
Interconnection
---
263