Functions For Service And Commissioning; Saving To External Storage Medium - Backup - Siemens SIMATIC HMI Series Operating Instructions Manual

Mobile panels 2nd generation
Hide thumbs Also See for SIMATIC HMI Series:
Table of Contents

Advertisement

Parameterizing the Mobile Panel

5.15 Functions for service and commissioning

4. Confirm your entries with "Save".
Note
For the "E-stop button evaluated by safety relay" and "E-stop button evaluated by
PROFIsafe" operating modes:
• If password protection is already enabled, the password prompt is displayed.
• If no password has been assigned, you are prompted to assign a password.
Enter the password and confirm your entry.
You can find additional information on password protection in the section
"Entering and deleting a password (Page 105)".
The dialog closes. Information text
Connection Box"
5. Close the "Safety operation" dialog with "Close".
The operating mode is assigned.
See also
Using the HMI device in password-protected security mode (Page 89)
5.15
Functions for service and commissioning
5.15.1
Saving to external storage medium – backup
You can use this function to back up the operating system, applications and data from the
flash memory of the HMI device to an external storage medium.
Use the following storage media:
● For KTP700, KTP700F, KTP900, KTP900F Mobile: A SIMATIC HMI Memory Card or an
industrial USB memory stick
● KTP400F Mobile: An industrial USB memory stick
144
shows: "Operation mode successfully stored in
Operating Instructions, 09/2018, A5E33876626-AC
Mobile Panels 2nd Generation