Installing Fan In Housing
• Attach the (2) wires to the spade terminals on the motor.
Insert fan into the fan housing starting with motor end
first. Slip it below the "L" bracket on the left side allowing
the right side to drop in. See Figure 3.29.
"L" Bracket
Wires attached to fan motor
Figure 3.29
Tilt the fan forward to clear the mounting brackets then
lift the fan onto the brackets. See Figure 3.30.
Mounting Brackets
Figure 3.30
Secure the fan to the mounting brackets with (4) screws
provided. See Figure 3.31.
Black
Figure 3.33
22
White
Junction Box Removed
Quadra-Fire • PIONEER - III • 4182-901 Installation Manual • Rev C • 07/19
Figure 3.31
Insert the fan wires through the grommet and into the
junction box. See Figure 3.32.
Fan Wires
Grommet
Figure 3.32
• Install the variable speed wall rheostat (with setting on
"OFF") in a convenient location. This switch will control
the Heat-Zone fan operation.
• Remove the junction box. Wire 110 VAC service TO
the wall rheostat and FROM the wall rheostat to the
fan junction box. Use wire nuts to secure the 110 VAC
service wires to the hot (black) and neutral (white) fan
wires and screw the 110 VAC ground wire to the junction
box. See Figure 3.33.
Secure the return air grille to the fan housing making
sure it is flush. The grille must be installed with the
louvers pointing down.
NOTICE:
DO NOT USE ADJUSTABLE REGISTERS.
14-2 w/ground
White
White
Black
Black
Screws
Incoming Power
(110V)