Quadra-Fire QVI30S Owner's Manual

Quadra-Fire QVI30S Owner's Manual

Installation and operation
Table of Contents

Advertisement

Model(s):
QVI30S
QVI35S
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
R
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber
or gas fi tter;
• a CO detector shall be installed in the room where the
appliance is installed.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire QVI30S

  • Page 1 • installation must be performed by a licensed plumber or gas fi tter; • a CO detector shall be installed in the room where the appliance is installed. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 Owner’s Manual Installation and Operation • Leave this manual with party responsible for use and operation.
  • Page 2 Serial Serial SIZE: #XXXXX #XXXXX #XXXXX #XXXXX (Serie): (Serie): Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 with local local codes, codes, if if any; any; if if not, not, follow follow ANSI ANSI Z223.1 Z223.1 (Installer l’appareil l’appareil selon...
  • Page 3: Table Of Contents

    E. Contact Information ......45 = Contains updated information. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09...
  • Page 4: Listing And Code Approvals

    A 110-120 VAC circuit for this product must be protected 31,000 19,000 with compliance with the applicable electrical codes, when it is 27,900 17,100 installed in locations such as in bathrooms or near sinks. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 WARNING ground-fault circuit-interrupter protection,...
  • Page 5: Getting Started

    • Installation and/or use of any component part not approved by Hearth & Home Technologies. Any such action may cause a fi re hazard. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 WARNING Inspect appliance and components for damage.
  • Page 6: Fireplace Size Requirements

    fl oor as tested for and as noted above. NOTE: For actual appliance dimensions refer to Section 15. TOP VIEW Minimum Appliance Size QVI35S Inches Millimeters Inches 24-1/4 13-5/8 22-3/4 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 QVI30S Millimeters 29-1/4 20-1/4 13-5/8 20-1/4...
  • Page 7: Clearances

    INLET AIR EXHAUST VENT PIPE VENT PIPE MANTEL Figure 3.2 Clearances to Mantels or other Combustibles above Appliance 12 in. MAX. 12 in. MIN. MEASUREMENTS FROM TOP EDGE OF UNIT Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09...
  • Page 8: Termination Locations

    • Terminations MUST meet minimum clearances. • Exhaust gases are hot. • Nearby vents may draw fumes into house. HORIZONTAL OVERHANG VERTICAL WALL ROOF PITCH IS X/ 12 H (Min.) Ft. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09...
  • Page 9: Vent Information And Diagrams

    TERMINATION CAP ADAPTOR EXHAUST VENT PIPE INSULATION SEAL INLET VENT AIR PIPE Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 WARNING Fire Hazard. Explosion Risk. Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl ue serving a separate solid fuel or gas burning appliance.
  • Page 10: Installation Preparation

    fi rebox of the wood- burning fi replace (see photo below). EXISTING BOTTOM OF Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 WARNING Fire Risk. This fi replace has been converted for use with a gas fi...
  • Page 11: Installing Vent Pipe And Appliance

    TERMINATION INLET AIR VENT PIPE INLET AIR STARTING COLLAR STARTING COLLAR BRACKET EXHAUST STARTING COLLAR Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 INLET AIR STARTING COLLAR LOCKING TAB STARTING COLLAR BRACKET EXHAUST STARTING COLLAR...
  • Page 12: Placing, Securing And Leveling The Appliance

    OR terminate within chimney. • Do NOT allow vent to sag below connection point to appliance. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 WARNING Fire Risk. Only an approved Hearth & Home Technologies surround may be used to cover integral grills on solid fuel burning fi...
  • Page 13: Installing Adaptor And Termination Cap

    THIS PIPE END! Note: Untwist the pipe while extending it, to achieve full 30’ length. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 CAUTION Sharp Edges • Wear protective gloves and safety glasses during installation. Note: The LINK-DV4-30B system REQUIRES this insulation.
  • Page 14: Gas Information

    Propane may have loosened during shipping. 11.0 inches w.c. 14.0 inches w.c. 10.0 inches w.c. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 WARNING Gas Leak Risk • Support control when attaching pipe to prevent bending gas line.
  • Page 15 To identify the proper orifi ce size, check with the local gas utility. If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09...
  • Page 16: Electrical Information

    • If desired an additional wall switch or thermostat may be added to system as shown in Figure 9.1). Follow directions included with the optional wall switch. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 WARNING Wire 110V to electrical junction box.
  • Page 17: Junction Box Installation

    Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. WARNING Shock hazard. • Replace damaged wire with type 105º C rated wire. • Wire must have high temperature insulation. JUNCTION BOX ACCESS SIDEWALL Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09...
  • Page 18 IT MUST BE REPLACED WITH TYPE C RATED WIRE. Figure 9.4 Fan/Rheostat Wire Diagram JUNCTION BOX GROUND 110-120 VAC BEND UP TABS Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 BLOWER RECEPTACLE BLOWER JUNCTION TEMPERATURE SENSOR SWITCH SPEED CONTROL (RHEOSTAT)
  • Page 19: Finishing

    INLET AIR 12 in. MAX. EXHAUST VENT PIPE VENT PIPE MANTEL 12 in. MIN. MEASUREMENTS FROM TOP EDGE OF UNIT Figure 10.1 Clearances to Mantels or other Combustibles above Appliance Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09...
  • Page 20: Appliance Setup

    • Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09...
  • Page 21: Refractory Placement

    fi rebox (see Figure 11.3). Figure 11.3 Step 3: Install the left side refractory in the same manner (see Figure 11.4). Figure 11.4 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 Refractory Placement MODELS: Supreme-XT, Grand-XT, QVI30, QVI35, ADI60 340-945B 6/02...
  • Page 22: Positioning The Logs

    Pull the log forward until the log is stopped by the back edge of the burner. The log should be centered. Log Set Assembly: LOGS-QVI30 BASEPAN BASEPAN Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 340-935 2/02...
  • Page 23 Log #3 (srv340-703): Position log #3 by locating its slot over the tab on the front right of the burner. Push the right side back against the step in the base pan. Log #4 (srv340-704): Place log #4 across log #1 and log #2 in the grooved out areas as shown. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09...
  • Page 24 #5 and the left end of the log sits in the horizontal carved out section of log #1. Log #7 (srv740-707): Small log #7 rests on the “ramp” on the backside of log #3. The burned out end of the log slopes down and to the left. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09...
  • Page 25 Log #2 (srv330-702): Position log #2 by locating its slot over the tab on the front left of the burner. The left end of log #2 is pushed up against the step in the base pan. Log Set Assembly: LOGS-QVI35 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 BURNER BURNER...
  • Page 26 Log #5 (srv330-704): Rest log #5 in the second smooth cut-out area on the end of log #1 and place the lower end on log #2. The “Y” end of the log sits on the right end of log #2. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09...
  • Page 27: Glass Assembly

    H. Air Shutter Setting Optimal fl ame appearance is dependent on the air shutter setting. Adjustments should be made by a qualified technician. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 Model QVI35S 1/2 in. Full Open (3/4 in.) QVI30S 3/8 in.
  • Page 28: Operating Instructions

    Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down.
  • Page 29: Lighting Appliance

    Bedroom or a Bedsitting Room. For assistance or additional informa- tion, consult a qualifi ed installer, ser- vice agency or the gas supplier. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 LIGHTING INSTRUCTIONS 1. Turn off all electric power to the appliance.
  • Page 30: Check Pilot Flame Appearance

    This will help avoid setting off smoke detectors, and help eliminate any odors associated with the appliance’s initial burning. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 WARNING Glass door must be in place when appliance is operating.
  • Page 31: Frequently Asked Questions

    Noise is caused by metal expanding and contracting as it heats up and cools down, similar to the sound produced by a furnace or heating duct. This noise does not affect the operation or longevity of the appliance.
  • Page 32: Troubleshooting

    Take a reading at the thermopile leads. The read- ing should be 325 millivolts minimum. Replace the thermopile if the reading is below the minimum. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 Corrective Action...
  • Page 33 Ensure that the glass is tightened properly on the unit, particularly on top corners. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 Corrective Action...
  • Page 34: Maintaining And Servicing Appliance

    Refer to maintenance instructions. • Combustible materials blocking cap may ignite. • Restricted air fl ow affects burner operation. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 CAUTION Handle glass assembly with care. NOTE: Clean glass after initial 3-4 hours operation.
  • Page 35 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. 3. Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure or leaking. Maintenance Tasks Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09...
  • Page 36: Reference Materials

    QVI30S LOCATION Inches Millimeters 29-1/32 20-5/32 10-3/32 32-5/16 27-25/32 12-7/16 22-23/32 20-1/4 21-5/32 8-7/16 REF Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 ELECTRICAL ACCESS MODEL DIMENSIONS QVI35S QVI30S Inches Millimeters Inches Millimeters 2-5/16 2-5/16 4-7/16 4-7/16 5-5/32...
  • Page 37: Vent Kits Components

    FLEX-CNCT: Connector kit - 3 inch liner to 3 inch liner, one connector per kit. LINK-DV4-30B Installation WARNING: DO NOT BLOCK THIS PIPE END! Figure 15.3 Direct Vent Flex Liner Accessory Kits Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 FLASH-DAMP LINK-ZC-ADP SVRLINK-ADP FLEX3-30 FLEX3-30/2 FLEX3-CNCT...
  • Page 38: Service Parts

    QVI30S C. Service Parts Service Parts Diagram Beginning Manufacturing Date: Aug. 2007 Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09...
  • Page 39 Regulator LP Additional service part numbers appear on following page. Service Parts Service Parts Diagram COMMENTS Pre Nov 2008 Post Nov 2008 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 QVI30S Stocked at Depot PART NUMBER LOGS-QVI30 SRV340-701...
  • Page 40 QVI35S Service Parts Service Parts Diagram Beginning Manufacturing Date: Aug. 2007 Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09...
  • Page 41 Pilot Orifi ce LP Regulator NG Regulator LP Additional service part numbers appear on following page. Service Parts Service Parts Diagram Post Nov 2008 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 COMMENTS PART NUMBER LOGS-QVI35 SRV330-701 SRV330-702 SRV330-703...
  • Page 42 Temp Sensor Switch Bracket: Burner Support Burner Wire Assembly Service Parts Service Parts Diagram COMMENTS Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 QVI30S, QVI35S Beginning Manufacturing Date: Aug. 2007 Ending Manufacturing Date: ______ PART NUMBER 2103-010 2103-011...
  • Page 43: Limited Lifetime Warranty

    D. Limited Lifetime Warranty Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09...
  • Page 44 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09...
  • Page 45: Contact Information

    DO NOT DISCARD THIS MANUAL • Read, understand and follow these instructions for safe installation and operation. Printed in U.S.A. - Copyright 2009 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 • Leave this manual with party responsible for use and operation.