NOTE
If the problem is solved before the delay time ends, no alarm is recorded in the history log.
Low Temperature Alarm Diff: Low temperature range beyond which alarm is activated.
High Temperature Alarm Diff: High temperature range beyond which alarm is activated.
Out Compensation: This parameter is added to the high temperature alarm when outside
temperatures are high, like noontime in desert countries. This feature ensures an alarm is not
triggered just because it is a hot day. The emergency temperature has no compensation, so the
compensation feature only works when temperatures do not exceed the emergency
temperature.
Example: Outdoor+comp. >Alarm then Alarm=Outdoor+Comp.
For example: IF the pre set compensation is 2°F, the outside temperature is 75°F and alarm is set
to 76°F, the controller adds the outside temperature to the comp, and the alarm rises to 77.
(75+2=77)
Figure 11: Out Temperature Compensation
Emergency Temperature: The temperature beyond which the controller goes into emergency
mode and an alarm is activated.
Variable Fan Stop: When in low temperature alarm, decide whether to keep variable speed in
minimum operation or totally shut down the function.
Water & Feed:
o Min/Max Water/Hour: The quantity of water per hour, below or above which the alarm
is activated.
o Min/Max Feed/Hour: The quantity of feed per hour, below or above which the alarm is
activated.
Auxiliary Alarm Related History: When assigning a related function, alarm occurs if the
associated digital input fails to follow the relay. Digital input must be active when its associated
relay is on.
If there is no related function the alarm turns on when digital input is active.