200/400 v class, single/three-phase input: 0.1/0.37 to 22/4.0/30 kw
Hide thumbs Also See for CIPR-GA50C Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10
10 Attachment
Mode
Terminal
l
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
2004
-, +1, +2
B1, B2
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
2006
-, +1, +2
B1, B2
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
2010
-, +1, +2
B1, B2
284
Recommen
Applicable
ded Gauge
Gauge
2
mm
mm
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
*2
*2
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
*2
*2
2.5
2.5
2.5
2.5 - 4
2.5
2.5 - 4
2.5
2.5 - 4
2.5
2.5 - 4
*2
4
2.5 - 6
YASKAWA TOMPC71061753A YASKAWA AC Drive GA500 Installation and Operation Instruction
Wire
Terminal Screw
Stripping
Length
*1
Size
2
mm
6.5
M3
6.5
M3
6.5
M3
6.5
M3
-
M3.5
6.5
M3
6.5
M3
6.5
M3
6.5
M3
-
M3.5
8
M3
8
M3
8
M3
8
M3
*2
-
M4
Tightening
Torque
Shape
N∙m (in∙lb)
0.5 - 0.6
(4.4 - 5.3)
0.5 - 0.6
(4.4 - 5.3)
0.5 - 0.6
(4.4 - 5.3)
0.5 - 0.6
(4.4 - 5.3)
0.8 - 1.0
(7.1 - 8.9)
0.5 - 0.6
(4.4 - 5.3)
0.5 - 0.6
(4.4 - 5.3)
0.5 - 0.6
(4.4 - 5.3)
0.5 - 0.6
(4.4 - 5.3)
0.8 - 1.0
(7.1 - 8.9)
0.5 - 0.6
(4.4 - 5.3)
0.5 - 0.6
(4.4 - 5.3)
0.5 - 0.6
(4.4 - 5.3)
0.5 - 0.6
(4.4 - 5.3)
1.2 - 1.5
(10.6 - 13.3)