10
Restore factory settings
The factory settings of the device can be re-
stored. If you do this, you will lose all your set-
tings.
To restore the factory settings of the blind actuator,
please proceed as follows:
•
Remove the rocker (if necessary).
Press and hold down the system button (A) for 4 s
•
with a pointed object (e.g. a pen) until the LED will
start flashing orange quickly (see figure 5).
•
Release the system button again.
•
Press and hold down the system button again for
4 seconds, until the status LED lights up green.
•
Release the system button to finish the procedure.
The device will perform a restart. After the restart, you can
again integrate your device into your Homematic IP system.
Test display
Restore factory settings
Once the test
display has stopped,
you can continue.
41