Homematic IP HmIP-BBL-2 Installation Instructions And Operating Manual page 31

Blind actuator for brand switches
Table of Contents

Advertisement

Available languages

Available languages

Hazard information
Exceeding this capacity could lead to the de-
struction of the device, fires or electric shocks.
The circuit to the which the device and the load
will be connected has to be secured by a cable
protection switch in accordance with EN60898-1
(tripping characteristic B or C, max. 16 A rated
current, min. 6 kA interrupting rating, energy lim-
iting class 3). Installation regulations according to
VDE 0100 and HD382 or 60364 have to be con-
sidered. Users must be able to easily access the
cable protection switch. This must be marked as
disconnecting device for the actuator.
Before the actuator is connected, remove the
fuse from the fuse box.
Except for configuration, the device may only be
operated with an associated switch cover.
The device has not been designed to support
safety disconnection.
Only shutters and blinds with limit switches (me-
chanical or electronic) should be used. Before
putting the actuator into operation, check that
the limit switches on the connected motors have
been adjusted correctly.
29