Fault Tracing - ESAB A6 S Arc Master Instruction Manual

Table of Contents

Advertisement

GB
7

FAULT TRACING

Equipment S
Instruction manual for control box A2--A6 Process Controller.
Operating manual for motor with gear A6 VEC,
S
order no. 0443 393.
Check
that the power source is connected for the correct mains supply
S
that all three phases are live (phase sequence is not important)
S
that welding cables and connections are not damaged
S
that the controls are correctly set
S
that the mains supply is disconnected before starting repairs
S
POSSIBLE FAULTS
1. Symptom Current and voltage readings show large fluctuations
Cause 1.1
Contact jaws or nozzle are worn or wrong size.
Action
Replace contact jaws or nozzle.
Cause 1.2
Feed roller pressure is too low.
Action
Increase pressure on feed rollers.
2. Symptom Wire feed is irregular
Cause 2.1
Feed roller pressure not correct.
Action
Change the feed roller pressure.
Cause 2.2
Feed rollers wrong size.
Action
Replace feed rollers.
Cause 2.3
Grooves in feed rollers are worn.
Action
Replace feed rollers.
3. Symptom Welding cables overheating
Cause 3.1
Poor electrical connection.
Action
Clean and tighten all electrical connections.
Cause 3.2
Cross--section of welding cables too small.
Action
Use cables with a larger cross--section or use parallel cables.