Technical Data; Accessories; Truma Warranty Policy - Truma Combi 2E CP plus Operating & Installation Instructions Manual

Gas heater and hot water generator, cp plus (australia)
Table of Contents

Advertisement

Disposal
The device must be disposed of in line with the administrative
regulations of the respective country in which it is used. National
regulations and laws must be observed.

Technical data

determined in accordance with EN 624 or Truma test conditions
Type of gas
LPG (Liquefied Petroleum Gas – propane / butane)
Operating pressure
2.75 kPa (see type plate)
Water contents
10 litres
Heating up time from approx. 15 °C to approx. 60 °C Boiler approx.
23 minutes (measured according to EN 15033) Heater + boiler approx.
90 min.
Pump pressure max. 0.28
MPa System pressure max.
0.45 MPa Nominal input
(Propane)
Combi 2 E CP plus (Australia):
Combi 4 E CP plus (Australia):
Thermal output
Electrical operation (240 V):
Mixed operation (gas and electrical): max. 3900 W
Gas operation
Combi 2 E CP plus (Australia):
Combi 4 E CP plus (Australia):
Gas consumption (Propane)
Combi 2 E CP plus (Australia):
Combi 4 E CP plus (Australia): 130 – 260 g/h Air delivery
volume (free-blowing without hot-air pipe) with 3 hot-air
outlets max. 249 m³/h with 4 hot-air outlets max. 287 m³/h
Current input at 12 V
Truma CP plus
Digital control panel Truma CP plus (part no. 36020-01).
Fig. 8
has been
Accessories (without picture) for control panels – Warranty repairs can only be performed by authorised ser- – Cable 3 m (part no. 36110-
01)
vice agents and under no circumstances will Dometic reim-
6.9 MJ/h
13.6 MJ/h
980 W / 1960 W
max. 1950 W
max. 3900 W
130 g/h

Truma warranty policy

Repairs will be carried out during normal business hours only by Dometic Pty Ltd, or its duly
authorised service agents, and are subject to the warranty conditions and exclusions
hereunder.
installed, to any authorised service agent. The pur-
Heater + boiler
Short-term max. 5.6 A (average power consumption 1.1 A)
Heating up of boiler: 0.4 A
Stand-by: 0.001 A
Current input at 240 V
4.1 A (980 W) or 8.1 A (1960 W)
Weight (not containing water)
Heater unit:
Heater unit with peripheral devices: 16.4 kg
Declaration of conformity
The heater Combi 2 E / 4 E CP plus (Australia) is approved according
AS 4552, AS 4556, AS/NZS 60335.2.21+A1-A3, AS/NZS
60335.2.30+A1, AS/NZS 60335.1+A1 and fulfills these standards:
5375
Dimensions
Fig. 7
The right to effect technical modifications is reserved!
The warranty is given by Dometic Pty Ltd, Building 3B,
Clayton Business Park, 1508 Centre Road, Clayton, Victoria, 3168,
for 12 months from the date of purchase against any defect arising
from faulty materials or workmanship.
Warranty conditions
– The company will only provide service on presentation of proof
of purchase, on either the Truma product, or the Caravan / RV /
Pleasure Craft in which the Truma product
chaser must allow the service agent to photocopy the proof of
purchase to facilitate his claim to the manufacturer.
– Cable 6 m (part no. 36110-02)
unauthorised persons. Tamper-
– Cable 9 m (part no. 36110-03)
by unauthorised personnel
will automatically void the warranty.
– The product must be used solely for domestic purposes only. If
the product is used for commercial purposes the warranty is 6
months only.
– Where applicable, the products must be used on the ap- propriate
electrical voltage, gas type and pressure, or fuel source.
– If at any time during the warranty period any part or parts are
replaced with a part or parts not supplied or approved by Truma,
this warranty shall immediately become void.
15.8 kg
burse repairs carried out by
ing with any part of the product
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combi 4e cp plus

Table of Contents