Trademark information What to do if you smell gas. Truma VarioHeat® eco AU referred to as VarioHeat below. – Extinguish all open flames – Open doors and windows – Close all quick-acting valves and gas cylinders –...
Page 3
– For vehicles, we recommend the Truma – Air from the discharge vent may be hot. Do MonoControl CS gas pressure regulation not place combustible materials directly in system and for two-cylinder systems, the front of the discharge vent.
Page 4
The operating permit for the appliance is also – If no safety shut-off device is installed (e.g. as void and, as a result, also the vehicle opera- contained in the Truma MonoControl CS gas tion permit in some countries. pressure regulation system), the gas cylinder must remain closed while the vehicle is mov- –...
More stickers can be obtained from Truma. The digital control panel allows other functions to be selected, Start-up such as a time switch or operation of a Truma air conditioning system. Information can be found in Truma CP plus VarioHeat digital control panel –...
Safety instructions Rotary push button – Use the Truma CP plus VarioHeat control panel only when it The rotary push button (8) is used to select and change set- is technically intact. points and parameters and to store them by tapping. Selected –...
Functions Selecting the fan speed The functions in the menu lines (3, 4) of the Truma CP plus VarioHeat control panel can be selected in any sequence. The With connected heater / air conditioning system operating parameters are shown in the status line (2) or the displays (5, 6).
If the RV is parked in an enclosed space: – Block the fuel feed (gas) to the heater. Fig. 14 – Deactivate the time switch of the Truma CP plus VarioHeat Selecting the fan speed control panel (OFF). – Use the rotary push button to select the desired fan speed.
OFFSET = -1 °C; trol panel. – Setpoint for heater = 22 °C – Switch on the power supply 12 V for the Truma CP plus VarioHeat control panel and Fig. 21 Truma VarioHeat and 230 V power supply for air conditioning systems.
If a command is sent via the infrared remote control of the air conditioning system, IR is displayed on the screen. In case of an error, the Truma CP plus VarioHeat control panel immediately goes to the menu level “Error” and shows the error code.
Heater without periphery: Maintenance of the Display 5.5 kg The Truma CP plus VarioHeat control panel requires no main- Subject to technical changes. tenance. To clean the front use a non-abrasive, moist cloth. If this is not sufficient, use a neutral soap solution.
Warranty conditions – The company will only provide service on presentation of proof of purchase, on either the Truma product, or the Caravan / RV / Pleasure Craft in which the Truma product has been installed, to any authorised service agent. The pur- chaser must allow the service agent to photocopy the proof of purchase to facilitate his claim to the manufacturer.
Troubleshooting guide for Truma VarioHeat Error Cause Rectification Flame not detected: # 16 – Gas cylinder or quick-acting valve in the gas – Check gas supply and open valves supply line closed – Gas pressure regulation system iced up – Use EisEx controller heater –...
Page 16
In Australia, always notify the Dometic Service Centre if problems are encountered; in other countries the relevant service partners should be contacted (www.truma.com). Having the equipment model and the serial number ready (see type plate) will speed up processing. Dometic Pty Ltd...