Truma VarioHeat Operating Instructions Manual

Truma VarioHeat Operating Instructions Manual

Advertisement

Truma VarioHeat
Operating instructions
Page 2
To be kept in the vehicle!

Advertisement

Table of Contents
loading

Summary of Contents for Truma VarioHeat

  • Page 1 Truma VarioHeat Operating instructions Page 2 To be kept in the vehicle!
  • Page 2: Table Of Contents

    Note containing information and tips. Start-up .................. 5 Room temperature sensor ..........5 Intended use Truma CP plus VarioHeat digital control panel .... 5 Intended use ................5 Safety instructions ..............6 This unit was designed for installation in motor homes (vehicle Important notes ..............
  • Page 3 – For vehicles, we recommend the cowl or the vehicle. Truma MonoControl CS gas pressure regu- lation system and the Truma DuoComfort / Obligations of the operator / vehicle owner DuoControl CS gas pressure regulation sys- – The vehicle owner is responsible for correct tem for two-cylinder gas systems.
  • Page 4 Maintenance / Repairs / Cleaning ing. The Truma MonoControl CS gas pressure regulation system satisfies this requirement. – The unit may only be repaired and cleaned Throughout Europe, a type-tested liquid gas by an expert.
  • Page 5: Function Description

    Function description Operating instructions VarioHeat is s warm air heater for air circulation to heat camp- Always observe the operating instructions and the “Im- ing vehicles quickly. The burner is fan-assisted, which ensures portant operating notes” prior to starting! The vehicle that operation is problem-free, even when on the move.
  • Page 6: Safety Instructions

    Safety instructions Rotary push button – Operate the Truma CP plus VarioHeat control panel only if it Setpoints and paramters can be selected and modified using is in a technically perfect condition. the rotary push button (8) and saved by tapping on it. Selected –...
  • Page 7: Functions

    Functions Select fan level The functions in the menu bars (3, 4) of the Truma CP plus VarioHeat control panel are selectable in any order. The op- With connected heating / air conditioning system erating parameters are shown on the status bar (2) and on the displays (5, 6).
  • Page 8: Set Time Switch

    – Select desired fan level with rotary push button. – Tap the rotary push button to confirm the value. – Switch off the heater at the Truma CP plus VarioHeat con- trol panel. – When air conditioning systems are being operated, the time switch of the Truma CP plus VarioHeat control...
  • Page 9: Switch Lighting On / Off

    – Select required function with rotary push button. Presetting: °C (Celsius). 3. Changing the background lighting 1 – 5 – Switch lighting on. Change the background lighting of the Truma CP plus VarioHeat Brightness selectable in 5 levels. control panel in 10 increments. – Switch lighting off.
  • Page 10: Special Displays

    Other connected appliances can be operated. Fault Figure 28 In the event of a fault, the Truma CP plus VarioHeat control Icon appears only in conjunction with a Truma air con- panel immediately jumps to the “Fault” menu level and dis- ditioning system.
  • Page 11: Technical Data, Display

    Subject to technical changes. Maintenance Maintenance The Truma CP classic VarioHeat control panel is maintenance- The Truma CP plus VarioHeat control panel is maintenance- free. In order to clean the front panel, use a damp, non-scour- free. In order to clean the front panel, use a damp, non-scour- ing cloth.
  • Page 12: Technical Data, Heater

    Technical data, heater Dimensions ( (all dimensions in mm) Determined in accordance with EN 624 or Truma test conditions Type of gas Liquid gas (propane / butane) Operating pressure 30 mbar (see type plate) Rated heat output (gas consumption) Truma VarioHeat eco 1300 W (100 g/h) / 2800 W (220 g/h)
  • Page 13: Manufacturer's Warranty (European Union)

    The warranty must be claimed with an authorised service part- towards the Consumer that covers any material and/or manu- ner or at the Truma Service Centre. All the relevant addresses facturing defects of the unit. and phone numbers can be found at www.truma.com, in the “Service”...
  • Page 14: Troubleshooting Guide, Truma Varioheat

    Troubleshooting guide, Truma VarioHeat Fault Cause Remedy Flame not recognised: – Gas cylinder or quick-acting valve in the gas – Check gas supply and open valves supply line closed – Gas pressure regulation system iced up – Use EisEx regulator heater –...
  • Page 15: Troubleshooting Guide, Truma Varioheat

    Troubleshooting guide, Truma VarioHeat Flashing code at the analogue CP classic control panel Flashing sequence - On / Off 0.5 seconds Pause between flashing sequence 5 seconds Fault Cause Remedy LEDs do not light up, – Automatic restart is blocked, e.g.
  • Page 16 Bei Störungen wenden Sie sich bitte an das Truma Las instrucciones de uso y de montaje en su idioma Servicezentrum oder an einen unserer autorisierten pueden solicitarse al fabricante Truma o al Servicio Servicepartner (siehe www.truma.com). postventa Truma en su país.