    Combi 2 E / 4 E CP plus (Australia) 1 Control panel (digital) 2 Room temperature sensor 3 Cold water connection 4 Hot water connection 5 Gas connection (with pressure test point – not shown) 6 Hot air outlets 7 Recirculated air intake...
  • Page 3: Symbols Used

    Function description Symbols used The unit must only be installed and repaired by an The Combi 2 E / 4 E CP plus (Australia) liquefied gas heater is expert. a warm-air heater with integrated hot water system (10 litre capacity). The burner is fan-assisted, which ensures that op- eration is problem-free, even when on the move.
  • Page 4: Safety Instructions

    Controller connecting hoses that meet na- cowl, tional regulations must always be used in the – failure to use original Truma parts as respective country for which the equipment is replacement parts and accessories, destined. These hoses must be checked regu- –...
  • Page 5: Important Operating Notes

    Important operating notes Operating instructions If the cowl has been placed near or directly beneath an opening window, the device must Always observe the operating instructions and “Impor- be equipped with an automatic shut-off device tant operating notes” prior to starting! The vehicle owner in order to prevent operation with the window is responsible for the correct operation of the appliance.
  • Page 6: Filling The Hot Water System

    Maintenance In order to check the water that is flowing out, place an appropriate container (capacity 10 litres) beneath the Only original Truma parts may be used for maintenance and drainage socket (d) of the safety/drain valve. repair work! – Open safety/drain valve The device must be descaled on a regular basis (at least twice (see “Opening the safety/drain valve”).
  • Page 7: Fuses

    Fuses Faults Faults – Heater Fuse 12 V Descriptions of possible fault causes and a troubleshoot- ing guide can be found in the operating instructions for the The fuse is in the electronics beneath the connection cover. control panel that is installed. Replace the unit’s fuse only with an identical fuse.
  • Page 8: Accessories

    Heater unit: 15.8 kg Heater unit with peripheral devices: 16.4 kg Declaration of conformity The heater Combi 2 E / 4 E CP plus (Australia) is approved according AS 4552, AS 4556, AS/NZS 60335.2.21+A1-A3, AS/NZS 60335.2.30+A1, AS/NZS 60335.1+A1 and fulfills these standards:...
  • Page 9: Truma Warranty Policy

    Warranty conditions – The company will only provide service on presentation of proof of purchase, on either the Truma product, or the Caravan / RV / Pleasure Craft in which the Truma product has been installed, to any authorised service agent. The pur- chaser must allow the service agent to photocopy the proof of purchase to facilitate his claim to the manufacturer.
  • Page 10 In Australia, always notify the Dometic Service Centre if problems are encountered; in other countries the relevant service partners should be contacted (www.truma.com). Having the equipment model and the serial number ready (see type plate) will speed up processing. Dometic Pty Ltd...

This manual is also suitable for:

Combi 4 e cp plus

Table of Contents

Save PDF