Truma Combi 2E CP plus Operating & Installation Instructions Manual

Truma Combi 2E CP plus Operating & Installation Instructions Manual

Gas heater and hot water generator, cp plus (australia)

Advertisement

Combi 2 E / 4 E CP plus (Australia)
Operating instructions
Installation instructions
Page 2
Page 9
To be kept in the vehicle!

Advertisement

Table of Contents
loading

Summary of Contents for Truma Combi 2E CP plus

  • Page 1 Combi 2 E / 4 E CP plus (Australia) Operating instructions Installation instructions Page 2 Page 9 To be kept in the vehicle!
  • Page 2 Combi 2 E / 4 E CP plus (Australia) 1 Control panel (digital) 2 Room temperature sensor 3 Cold water connection 4 Hot water connection 5 Gas connection (with pressure test point – not shown) 6 Hot air outlets 7 Recirculated air intake 8 Waste gas discharge 9 Combustion air infeed 10 Electronic control unit 11 Water container (10 litres)
  • Page 3: Table Of Contents

    If the boiler has been filled, the water is Accessories ................. 8 automatically heated as well. The water temperature depends on the Truma warranty policy ............. 8 selected operating mode and the heater output. Installation instructions All 3 energy selection options can be used for winter deployment.
  • Page 4: Instructions

    – modifications to the exhaust duct and the cowl, clear so that the unit does not overheat. – failure to use original Truma parts as replacement parts and accessories, Do not use any after market air filters or air grills.
  • Page 5: Start-Up

    Maintenance boiler, the boiler also fills up with water. To avoid frost damage, the boiler must be drained via the safety/drain valve, Only original Truma parts may be used for maintenance and repair even if it was not operated. work! In the event of frost, filling may be prevented by residual water that The device must be descaled on a regular basis (at least twice a year).
  • Page 6: Fuse 12 V

    Servicing shall be carried out only by authorised personel. Overheating protection 240 V Please contact Dometic Service Centre for service and repairs. The 240 V heating facility has a mechanical overheating switch. If the 12 V power supply is interrupted during operation or during the Biofilm, deposits and limescale must be removed using chemicals to after-run period, for example, the temperatures within the unit could protect the unit from infestation by microorganisms.
  • Page 7: Technical Data

    Warranty conditions – The company will only provide service on presentation of proof of purchase, on either the Truma product, or the Caravan / RV / Pleasure Craft in which the Truma product Fig. 8 has been installed, to any authorised service agent.
  • Page 8: Installation Instructions

    Intended use The year when the equipment was first taken into operation must The Truma Combi 2 E / 4 E CP plus (Australia) liquid gas heater is a warm-air heater with integrated hot water boiler (10 litre capacity). be indicated with a check on the type plate.
  • Page 9: Regulations

    – modifications to the exhaust duct and the cowl, temperatures can occur at the base of the unit. – failure to use original Truma parts as replacement parts and In order to prevent damage to components inside the equipment, accessories, no cables or water lines of any kind may be attached to the –...
  • Page 10: Securing The Device

    Only Truma exhaust duct AA 3 (part no. 39320-00) and combustion air infeed ZR (part no. 39580-00) may be used for the Truma Combi Slide on clip (2) as far as it will go (end position must be between 2 E / 4 E (Australia) heater because the unit was tested and claws of clip) and screw in place.
  • Page 11: Gas Connection

    Only Truma ducts are approved with the heating system and must be used. Use only pressure-safe ducts in compliance with Truma quality requirements. Other ducts that do not meet our quality standard (particularly crown pressure resistance, duct diameter and number of grooves) must not be used.
  • Page 12: Water Connection

    John Guest pipes, insertion sleeves and hose clamps. As accessories Truma supplies the water connectors (27 + 28) and safety/drain valve (24) with a 10 mm / 3/8” diameter hose nipple. The included elbow fittings (27 + 28) must always be used in...
  • Page 13: Control Panel

    A water pipe (hose) may only be fitted at a clearance of 1.5 m to the heater on the warm air duct. The Truma hose clip SC can be used if this distance is observed. In the case of parallel installations, e.g.
  • Page 14: 12 V Voltage Supply

    < 1.2 Vpp. We recommend the the war ning information, which is enclosed with the appliance, to a automatic chargers from Truma for the different applications. Please place in the vehicle where it is clearly visible to all users (e.g. on the ask your dealer.
  • Page 15 In Australia, always notify the Dometic Service C entre if problems are encountered; in other countries the relevant service partners should be contacted (www.truma.com). Having the e quipment model and the serial number ready (see type plate) will speed up processing.
  • Page 16 Dometic Pty Ltd Building 3B, Clayton Business Park Dometic New Zealand Ltd. Service Service (Australia) (New Zealand) 1508 Centre Road Post Box 12011 Clayton, Victoria, 3168 Telephone:+ 61 (0)3 92 39 10 50 1642 Penrose, Auckland Telephone +64 (0)9 622 14 90 Australia Facsimile: +61 (0)3 92 39 10 99 New Zealand...