Service Diagnostics and Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect gas supply and electrical power to unit
before servicing. Discharge capacitor through a resistor before attempting to service. Wires removed during
disassembly must be replaced on proper terminals to insure correct earth ground and polarization. After
servicing, reconnect electrical power and gas supply. Before placing appliance into operation, always check
for gas leaks with soapy water solution. DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.
Landing Ledge–VDSC548T
To access control panel, light and left oven switches,
gas valves, spark module, and griddle module:
1a. VDSC548T–6GQ: remove knobs and screws
securing burner and oven control bezels.
Screw
1b. VDSC548T–6G: remove knobs and screws
securing burner and oven control bezels.
Screw
1c.
VDSC548T–6Q: remove knobs and screws
securing burner and oven control bezels.
Screw
© 2011 Viking Preferred Service
WARNING
2.
Open oven door and remove screws securing
landing ledge.
Screw
3.
Lift up on control panel to disengage from
keyhole slots.
4.
Lower landing ledge and disconnect control
ribbon and oven light switch wires.
Screw
Key hole Screw
Control Ribbon
Screw
90