Service Diagnostics and Procedures–Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power to unit using power
switch before servicing. Wires removed during disassembly must be replaced on proper terminals to insure
correct earth ground and polarization. After servicing, reconnect power using power switch.

Convection Element

To access Convection Element:
1.
Remove convection fan cover (see Convection
Fan Cover section, page 109).
2.
Remove screws that attach the convection bake
element to the oven liner.
Screw
Screw
3.
Disconnect two wires from convection element.
4
Reverse procedure for installation.

Smoke Eliminator

To access Smoke Eliminator:
1.
Remove convection fan cover (see Convection
Fan Cover section, page 109).
2.
Remove the screws that hold the smoke
eliminator to the top, left, and rear corner of
the oven liner.
3.
Pull down the smoke eliminator to remove
from oven liner.
4.
Repair/replace element as necessary.
© 2011 Viking Preferred Service
Convection
Fan Assembly
Connectors
Screws
Smoke Eliminator
WARNING
Interior Light bulb Replacement
DO NOT touch bulb with bare hands. Clean off
any signs of oil from the bulb and handle with
a soft cloth.
1. Unsnap glass light cover using a screwdriver in
the access groove.
2. Firmly grasp light bulb and pull out.
3. Replace with halogen bulb using volt and
wattage requirements listed on glass cover.
4. Replace the light cover by snapping glass cover
onto metal box.