Specification
OPC Server (optional)
Pwd Net Sync (optional)
Extra Pens (4 pens)
(optional)
*Specification table for Sterilisation: The definition of Fo/Po is the sterilisation/pasteurisation time in minutes required to destroy a stated number
of organisms with a known z at temperature T. For example, "F18/250" represents the time in minutes required to destroy a stated number of
organisms at a temperature of 250°F (121.11°C) with a z = 18 degrees F. F values are used to compare the sterilizing values of different proc-
esses, however, F values cannot be compared unless the z values are the same. When temperature is not specified (for example, F = 8.6) it
is understood that the temperature is 250°F (121.11°C); the subscript O (as in the term Fo = 7.4) is used to indicate that the z = 18 degrees F
and the temperature is 250°F (121.11°C).
Specification
Parameter
Ambient Temperature
Relative Humidity (%RH)
Vibration
Frequency (Hz)
Acceleration (g)
Mechanical Shock
Acceleration (g)
Duration (ms)
Mounting Position from Vertical
Tilted Forward
Tilted Backward
Tilted to Side (+/-)
Power Requirements
Mains Voltage (Vrms)
Low Voltage AC (Vrms)
DC Voltages
Frequency (Hz)
Power Consumption
Warm Up
Seismic Qualification
* The maximum rating only applies up to 104°F (40°C). For higher temperatures, the RH spec is de-rated to maintain constant moisture content
266
OPC Server (Open Process Control) - Software application for realtime interfacing between servers and
clients. OPC is a software standard that defines common interfaces for data exchange between devices
such as recorders, controllers, PCL's and Windows™ based applications. OPC 3.0 DA & AE compliant.
Totalisers and up to 96 pens can be transmitted via OPC server, max poll rate 1/s.
Password Network Synchronisation. Password can be synchronised over the network, a recorder can be
designated as a master of a password group and other recorders can be added to that group as slaves,
the master will ensure all passwords are synchronised with all recorders in its group. up to 32 recorders
can be in a Password group, this include the password Master.
4 extra pens to store and display totalised values, results of calculations, etc. Maximum is up to 16 extra
pens for the Minitrend QX, 12 extra pens for the eZtrend QXe recorders, and 48 extra pens for the Multi-
trend SX recorder.

Environmental and Operating Conditions

Reference
67 °F to 77 °F
19 °C to 25 °C
50 to 65*
0
0
0
0
220 to 240
24 +/- 2
24 +/- 2
49.8 to 50.2
QX/QXe: AC: <40W (max), DC: <40W (max) Typical 20W.
SX: AC: <60W (max), DC: <60W (max) Typical 30W
30 minutes minimum
Complies with IEEE 323-1974 and/or 1983 and IEEE 344-1975 and/or 1987 (option). Hard-
ware includes an IEC bracket.
Options
Rated
Extreme
32 °F to 122 °F
32 °F to 122 °F
0 °C to 50 °C
0 °C to 50 °C
10 to 90*
5 to 90*
0 to 70
0 to 100
0.1
0.2
1
5
30
30
40°
40°
65°
65°
65°
65°
100 to 250
90 to 264
20 to 30 QX/SX
20 to 30 QX/SX
20 to 25 QXe
20 to 25 QXe
20 to 55 QX/SX
20 to 55 QX/SX
20 to 30 QXe
20 to 30 QXe
47 to 63
47 to 63
Transport & Stor-
age
14 °F to 140 °F
–10 °C to 60 °C
5 to 95*
0 to 100
0.5
20
30
Any
Any
Any
N/A
N/A
N/A
N/A
43-TV-25-30 Iss.6 GLO Aug 07 UK