When the configuration is complete select the Finish button to Commit. Select the Back but-
ton to return to the previous menu.
(Main Menu > Configure > Passwords > User Admin > Levels)
The Level permissions are the 4 user levels that have been set up and named in the Policy
menu eg. Engineer, Supervisor, Technician and Operator.
Select each user level eg. Engineer, and setup the permission areas for that particular level
of user. Each Permission Area will give the user access to selected menus in the recorder.
The level permission has a set of default settings that are defined in
on page
on page 130.
(Main Menu > Configure > Passwords > User Admin. > Add User)
The Administrator enters each new user name, then selects the new user and assigns their
Level of permission. The Administrator can set up a new user but cannot assign a password.
A dummy password is set and the new user is prompted to change the password when they
first Log on.
The same user name cannot be used. User names must not contain numeric characters.
The Administrator can add more than one user at a time. They will not be added until the
configuration has been Committed. When the configuration is complete select the Finish
button to Commit.
When a new user is added a default password ("password") is set. When a new user first
logs on they are prompted to change the password. The new user is responsible for remem-
bering their own password. The Administrator will not be able to access this information. But
the Administrator is able to reset the password for any user.
43-TV-25-30 Iss.6 GLO Aug 07 UK
• Username Min - Set the minimum amount of characters that can be used for the User
name login. (1 to 20 character and 0 will disable, 4 to 20 characters and no disable for
ESS recorders)
• Password Min - Set the minimum amount of characters that can be used for the Pass-
word login. (1 to 20 characters, 0 will disable, 6 to 20 characters and no disable for ESS
recorders)
• Min Alpha - Set the minimum amount of alpha characters to be used in the Password.
(0 to 20 characters)
• Min Symbol - Set the minimum amount of symbol characters to be used in the Pass-
word. (0 to 20 characters)
• Min Numeric - Set the minimum amount of numeric characters to be used in the Pass-
word. (0 to 20 characters)
• Pass Retries - Set how many times the incorrect password can be entered before the
user account is locked out. (1 to 10 retries, 0 will disable, 1 to 6 retries and no disable
for ESS recorders)
• Pass Expiry - Set how many days before the current passwords will expire. (1 to 365
days and 0 will disable. For ESS recorders 1 to 180 days and no disable)
• Expiry Warning - Set how many days before the passwords expiry date that a warning
notice will appear. (1 to 20 days and 0 will disable, no disable for ESS recorders)

Levels

173. Permission areas can be customised for each level if required, see

Add User

"Level Permissions"
"Users"
129