The display shows P6. The unit is now in the mode "Blocking Force for gate
opener 2"

P6 Adjusting the Blocking Force for Gate Opener 2

1.
Press the button INC or DEC in order to start settings.
Factory setting for the sensitivity is 3. Settings from 1 – 9 are possible. Each
time you press the button INC, the value will increase and when pressing the
button DEC, the value will decrease.
2.
Press the button FUNC in order to store the settings.
Hint: You may need to increase the blocking force in cold weather due to
increased resistance from the gate hinges.
The display shows P7. The unit is now in the mode "Closing Time for gate
opener 1".

P7 Closing Time for Gate Opener 1

1.
Press the button INC or DEC in order to adjust the closing time.
Factory setting for the closing time is 30 seconds. Settings from 0 – 40
seconds are possible. Each time you press the button INC, the value will
increase and when pressing the button DEC, the value will decrease. Hold
the buttons INC or DEC pressed in order to speed up the value.
2.
Press the button FUNC in order to store the settings.
The display shows P8. The unit is now in the mode "Closing Time for gate
opener 2".

P8 Closing Time for Gate Opener 2

1.
Press the button INC or DEC in order to adjust the closing speed.
Factory setting for the closing time is 30 seconds. Settings from 0 – 40
seconds are possible. Each time you press the button INC, the value will
increase and when pressing the button DEC, the value will decrease. Hold
the buttons INC or DEC pressed in order to speed up the value.
2.
Press the button FUNC in order to store the settings.
The display shows P9. The unit is now in the mode "Photocell Beam System"
(not available).

P9 Photocell Beam System

1.
Press the buttons INC or DEC and set 00. 00 indicates that the photocell
beam system is deactivated. If the setting 00 is not set, the gate opener will
not function.