Item
CAM1 to CAM99 IP
ADDRESS
CAM1 to CAM99 PORT
CAM1 to CAM99 INF
UPLOAD
NOTE
Performing [UPLOAD] after changing the settings will apply the setting value changes. Perform [UPLOAD] on each screen. The
settings will not be applied unless [UPLOAD] is performed.
Sets the IP address of the camera.
The setting ranges are as follows.
(IP addresses are assigned in order starting with 192.168.0.20 for CAM1 under factory default con-
ditions.)
1st octet: 1 to 223
2nd octet: 0 to 255
3rd octet: 0 to 255
4th octet: 1 to 254
However, the following addresses cannot be set.
Check the setting values during configuration.
0.*.*.*, *.*.*.0, *.*.*.255, 127.0.0.1
Class D address (224.0.0.0 to 239.255.255.255)
Class E address (240.0.0.0 to 255.255.255.255)
Sets the port of the camera.
Values from 1 to 65535 can be set.
(Factory default: 49152)
When you press the [MENU] dial, the camera's IP address and port will be set.