Judging Times / Az Times / At Start Nz Confirmation / At Start Wv Confirmation /Auto Jog (On/Off) / Auto Jog Timer - Unipulse F159 Operation Manual

Plug-in weight module for the omron sysmac cji series plc
Table of Contents

Advertisement

m+28
m+20
m+21
m+22
6-8. Judging Times / AZ Times / At Start NZ Confirmation /
At Start WV Confirmation /Auto Jog (ON/OFF) / Auto Jog Timer
Judging times
F159 can perform Over/Go/Under comparison when the measuring process is
completed (synchronized with Complete signal). This two-digit number (00-99)
specifies the frequency at which the comparison takes place.
00 : comparison disabled
01 : every time
02 : once in every two outputs
03 : once in every three outputs
99 : once in every 99 outputs
6.WEIGHING MODE SETTING AND OPERATION
0
0
0
10
10
10
0
-1
10
10
0
-1
10
10
0
-1
10
10
0
10
Sign convention for discharge control
Complete signal output mode
2:Complete signal turns on when turns
on, and remains on until Compare
time expires, or, It turns on when
r e a d i n g b e c o m e s " s t a b l e " a n d
remains on until Complete output
time expires.
1 :A f t e r C o m p a r e t i m e e x p i r e s ,
Complete signal turns on when
r e a d i n g b e c o m e s " s t a b l e " a n d
remains on until Complete output
time expires.
0:Complete signal turns on when
Compare time expires, and remains
o n u n t i l C o m p l e te o u tp u t ti m e
expires.
Upper/Lower limit comparison mode
Over/Under comparison mode
-2
Comparison inhibit time 0.00 - 9.99
10
-2
10
Compare time
-2
10
Complte output time
0.00 - 9.99
0.00 - 9.99
83