1-3. Unit Number Select Switch

F159 acts as a high performance weighing processing module for Omron SYS-
MAC CJ1 series PLC. The data exchange between CPU unit and F159 are
carried out by the high performance relay area of I/O and DM area.
Relay and DM number used by F159 can be selected by the unit number
selection switch located on the front panel.
Switch
Unit
No.
No.
0
1
2
3
4
5
6
7
8
9
10
95
Unit number must be unique: duplicate use of the same number for multiple of
I/O units will cause operation error "Error: Duplicate use of unit No."
("Duplicate use of unit No." in programming console), disabling normal
operation (A40113 turns ON).
Channel number allocated
to the I/O unit relay area
0
2000 - 2009CH
1
2010 - 2019CH
2
2020 - 2029CH
3
2030 - 2039CH
4
2040 - 2049CH
5
2050 - 2059CH
6
2060 - 2069CH
7
2070 - 2079CH
8
2080 - 2089CH
9
2090 - 2099CH
10
2100 - 2109CH
2000 + n × 10 - 2000 + n × 10 + 9CH
95
2950 - 2959CH
1.APPEARANCE DESCRIPTION
DM number allocated
to the I/O unit DM area
D20000 - 20099
D20100 - 20199
D20200 - 20299
D20300 - 20399
D20400 - 20499
D20500 - 20599
D20600 - 20699
D20700 - 20799
D20800 - 20899
D20900 - 20999
D21000 - 21099
D20000 + n × 100 - D20000 + n × 100 + 99
D29500 - 29599