6-2. Simple Comparison Control and Sequence Control

6-2-1. Simple Comparison Control

The simple comparison method compares the measured weight value with the
discharge setting at a regular interval. The system outputs "1" when the preset
condition is satisfied.
In this control method, the next control operation is only enabled when measured
weight falls below 75% of the previous Final value.
Final - FF CPS.
Final - SP2
Final - SP1
Near zero
Near zero
SP1
SP2
SP3
Comparison
inhibit time
Compare time
Stable
Complete
Complete
output time
Over
Go
Under
NET
Final
0
OFF
ON
t1
6.WEIGHING MODE SETTING AND OPERATION
ON
ON
t1
t2
ON
ON
ON
OFF
Over
Under
Time
ON
t3