Status Led - Unipulse F159 Operation Manual

Plug-in weight module for the omron sysmac cji series plc
Table of Contents

Advertisement

1.APPEARANCE DESCRIPTION

1-2. Status LED

Status LEDs display the current operating status of the unit. The following table
summaries their names and meanings.
(Green)
(Orange)
(Orange)
2
LED
Name
RUN
Operation status
ERC
Error detected
by the unit
(Red)
ERH
CPU error
(Red)
WERR
Weight error
(Red)
OUT1
OUT1 output
OUT2
OUT2 output
State
Description
ON
Normal operation
OFF
Data exchange with CPU has been aborted
ON
Error occurred in F159
OFF
Normal operation
ON
Error occurred during data exchange with CPU
OFF
Normal operation
One or more of the following alarms are in
ON
place: ± LOAD, OFL1, OFL2, OFL3, ZALM
OFF
Normal operation
ON
OUT1 =ON
OFF
OUT1 = OFF
ON
OUT2 = ON
OFF
OUT2 = OFF

Advertisement