1.APPEARANCE DESCRIPTION
1-4. DIP Switch
DIP switch is used to LOCK calibration and restore default settings.
When switch 2 is set to ON position, F159 initializes set value whenever F159 is
powered on.
Switch 3 and 4 are undefined: they should always be set to OFF position. When
they are set to ON position, F159 can't operate normally.
4
Switch No.
ON
1
Calibration LOCK ON
2
Default set ON
3
Undefined
4
Undefined
CAUTION
R R
W E
O U T
1
2
9
O U T
F 1 5
U N
R
E R C
E R H
H
M A C
N o .
1
1 0
0
1 0
DIP switch
NO
State
OFF
Calibration LOCK OFF
Default set OFF
Undefined
Undefined
Terminal block can be detached by
pulling down the lever. Normally, the
lever should be in upper position.
Always turn off the CJ1's voltage
source before trying to attach/detach
the terminal block.