E02D09/ Suction Fan Lock Error; E02E01/ E02E05/ E02E06/ Carriage Motor Error; E02E10/ Ieee1394 Error; E02F00/ System Controller Internal Error - Canon WS8400 Service Manual

Table of Contents

Advertisement

6.1.4.30 E02D09/ Suction fan lock error

<Cause>
Lock signal is detected longer than prescribed interval while driving the suction fan.
<Probable problem locations>
Suction fan, engine controller and system controller
<Remedy>
1. Suction fan
Check operation by using SERVICE MODE>FUNCTION>PLATEN FAN, and replace if there are any abnormalities.
2. Cable connection check
Replace the cable connecting the suction fan and motor driver if the connection is not functioning properly.
3. Replace the motor driver.
4. Cable connection check
Replace the cable connecting the suction fan and engine controller if the connection is not functioning properly.
5. Replace the engine controller.
6. Replace the system controller.

6.1.4.31 E02E01/ E02E05/ E02E06/ Carriage motor error

<Cause>
This is displayed when a jam or other physical problem puts an excessive load on the carriage motor so that the carriage could not operate.
This is displayed when the carriage motor could not reach the prescribed speed within the prescribed time.
<Probable problem locations>
Foreign object in carriage movement path, carriage rail, carriage belt, linear scale, linear encoder, carriage motor, engine controller, system controller
<Remedy>
1. Carriage movement path check
Remove any foreign objects (jammed sheet) in the carriage movement path.
2. Carriage rail
Use rail cleaner to clean the carriage rails if a visual check reveals that they are dirty.
3. Carriage belt
If a visual check reveals slack in the carriage belt, remount the belt.
4. Replace the linear scale.
5. Replace the linear encoder.
6. Replace the carriage motor.
7. Cable connection check
Replace the cable between the carriage motor and engine controller if the connection is not functioning normally.
8. Replace the engine controller.
9. Replace the system controller.

6.1.4.32 E02E10/ IEEE1394 error

<Cause>
This is displayed when an error has occurred in the IEEE1394 interface.
<Probable problem locations>
IEEE1394 interface board, system controller
<Remedy>
1. Turn the power off and then on again.
2. IEEE1394 interface board
Remount the IEEE1394 interface board, and then turn on the power again.
Replace the IEEE1394 interface board if it still is not functioning normally.
3. Replace the system controller.

6.1.4.33 E02F00/ System controller internal error

<Cause>
This is displayed when an error has occurred in the firmware of the system controller.
<Probable problem locations>
System controller
<Remedy>
1. Turn the power off and then on again.
2. Replace the system controller.

6.1.5 Troubleshooting When Service Call Errors Occur

6.1.5.1 Outline

When a service call error occurs, the error is not cleared and the error display remains on the operation panel even if printer power goes off and on.
This is to avoid thet the user can cleare service call errors preventing the printer from damage.
Service call errors can be cleared, however, by starting up the printer with the service mode.
Codes in parentheses are not displayed when a service call error occurs.
These codes can be checked in the error history by using SERVICE MODE> DISPLAY> ERROR.
Chapter 6
0010-0052
0009-7112
0009-7119
0009-7120
0009-7121
6-13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

W8400 seriesW8400pg

Table of Contents