Chapter 6
<Countermeasure>
1. Replace the mist fan.
2. Cable continuity check
If continuity of the cable between the mist fan and the main controller PCB is abnormal, replace the cable.
3. Replace the main controller PCB.

6.1.3.16 03130031-2F17 Suction fan error

iPF6000
<Cause>
When the suction fan was driven, the lock signal was detected for more the specified time.
<Probable fault location>
Suction fan or main controller PCB
<Countermeasure>
1. suction fan
Select [SERVICE MODE]>[FUNCTION]>[PLATEN FAN] to check the suction fan for normal operation. If the operation is abnormal, replace the suction fan.
2. Cable continuity check
If continuity of the cable between the suction fan and the main controller PCB is abnormal, replace the cable.
3. Replace the main controller PCB.

6.1.3.17 03130031-2F20/03130031-2F28/03130031-2F22/03130031-2F23 Defective sensor in purge unit

iPF6000
<Cause>
The pump cam sensor in the purge unit could not detect the home position of the purge motor within the specified time.
<Probable fault location>
Purge unit or main controller PCB
<Countermeasure>
1. Cable continuity check
If continuity of the cable between the pump cam sensor, pump motor and main controller PCB is abnormal, replace the cable.
2. Replace the purge unit.
3. Replace the main controller PCB.

6.1.3.18 03130031-2F24 Cutter drive time-out error

iPF6000
<Cause>
After the cutter motor was driven of the cutter unit, cutter right detection sensor or cutter HP sensor ON was not able to be detected in the regulation time.
<Probable fault location>
Cutter right position sensor, cutter HP sensor, cutter motor, cutter unit, cutter driver PCB, or main controller PCB
<Countermeasure>
1. Visual check
Remove foreign substances from the cutter unit if any.
2. Cutter right position sensor and cutter HP sensor
Select [SERVICE MODE]>[I/O DISPLAY] to check for normal operation. If the operation is abnormal, replace the feed roller HP sensor.
3. Cable continuity check
If continuity of the cable between the cutter right position sensor, the cutter HP sensor, the cutter motor and the cutter driver PCB is abnormal, replace the cable.
4. Replace the cutter motor.
5. Replace the cutter unit.
6. Replace the cutter driver PCB.
7. Cable continuity check
If continuity of the cable between the cutter driver PCB and the main controller PCB is abnormal, replace the cable.
8. Replace the main controller PCB.

6.1.3.19 03130031-2F25 Carriage home position error

iPF6000
<Cause>
The carriage home position could not be detected within the specified time.
<Probable fault location>
Carriage stopper, linear scale, linear encoder, carriage PCB, or main controller PCB.
<Countermeasure>
1. Visual check
Remove foreign substances from the carriage stopper, the linear scale and linear encoder if any.
2. Replace the linear scale.
3. Replace the linear encoder.
4. Cable continuity check
If continuity of the cable between the linear encoder and the carriage PCB is abnormal, replace the cable.
5. Replace the carriage PCB.
6. Cable continuity check
If continuity of the cable between the carriage PCB and the main controller PCB is abnormal, replace the cable.
7. Replace the main controller PCB.