Measuring points
Measuring points after the
connection outlet. Fan curves
indicate the total pressure
available for duct losses.
Supply air
Extract air
SEEN FROM ABOVE
Input power of the unit
Fan control voltage
Input power of
with SC controller
the unit
(V)
(W)
3
11
4
15
5
20
6
26
7
37
8
49
9
65
10
87
11,4
108
Sound
Sound power level in supply air duct (one duct)
values
ADJUSTMENT POSITION/AIR FLOW dm
Adjustment position
11,4 V
10,0 V
54,6
50,4
Air fl ow dm
/s
3
Medium
63
57,6
57,4
frequency
125
60,4
59,3
of the
octave
250
64,0
62,3
band Hz
500
66,2
64,3
1000
63,2
61,5
2000
58,8
56,9
4000
53,6
51,4
8000
36,5
33,4
L
,dB
70,6
68,9
W
L
, dB(A)
67,5
65,6
WA
Sound pressure level coming from the unit through the envelope in the rooms where the unit has been installed
11,4 V
54,0 / 61,4
L
, dB (A)
49,2
pA
6
Performance TSK Multi 50 MC
Air volumes Vallox TSK Multi 50 Supply air (F7 + G4), Extract air (G4)
E = Extract air fan
S = Supply air fan
300
250
200
150
100
E 5,0 V
S 5,0 V
E 4,0 V
50
S 4,0 V
E 3,0 V
S 3,0 V
0
0
10
by octave band L
, dB
W
9,0 V
8,0 V
7,0 V
6,0 V
5,0 V
43,9
38,7
31,3
25,1
18,8
54,1
52,8
50,2
47,3
44,9
57,3
55,6
53,7
50,0
51,1
61,0
59,9
58,5
55,1
51,2
61,8
60,8
55,2
50,0
45,5
59,6
56,6
51,
47,5
42,3
54,3
51,3
47,4
41,9
34,4
48,1
43,9
38,0
*29,6
*23,1
*29,6
*26,5
*24,3
*23,3
*23,1
66,8
65,2
62,0
58,1
55,4
63,3
61,1
57,0
52,3
47,6
ADJUSTMENT POSITION/AIR FLOWS (supply/extract)
10,0 V
9,0 V
49,3 / 55,8
43,9 / 50,1
38,1 / 44,0
47,7
45,6
ED and SD are examples of pressure
losses in supply and extract ducts.
E 11,4 V
S 11,4 V
E 10,0 V
S 10,0 V
E 9,0 V
S 9,0 V
E 8,0 V
S 8,0 V
E 7,0 V
S 7,0 V
E 6,0 V
S 6,0 V
20
30
40
Volume fl ow rate (dm
Sound power level in extract air duct (one duct)
/s
ADJUSTMENT POSITION/AIR FLOW dm
3
4,0 V
3,0 V
11,4 V
10,0 V
13,8
8,1
62,8
56,9
40,7
42,3
51,0
50,0
47,8
40,5
57,8
57,0
45,9
34,9
55,3
53,9
39,5
30,1
51,0
50,2
35,5
*24,0
51,1
49,3
*23,9
*17,8
40,1
38,4
*20,6
*18,6
33,0
31,1
*23,1
*23,2
*23,5
*23,2
50,9
45,2
61,3
60,2
41,5
32,5
54,1
52,7
(10m
sound absorption)
2
8,0 V
7,0 V
6,0 V
31,5 / 37,3
25,1 / 30,9
42,9
39,3
35,6
*The background noise requirements of standard ISO 3741:2010 have not been met
© VALLOX • We reserve the right to make changes without prior notice.
What the units include can vary depending on the sales area.

TECHNICAL DATA

SFP (Specifi c Fan Power) recommended value <2.5 (kW m
Input power (total) (W)
SFP =
Air fl ow (max) (dm
/s)
3
ED
SD
50
60
70
/s)
3
by octave band L
, dB
W
9,0 V
8,0 V
7,0 V
6,0 V
5,0 V
50,3
45,0
37,9
32,1
26,2
47,6
45,5
43,4
*38,2
*34,0
54,5
51,9
49,2
48,0
44,7
52,7
52,1
48,6
47,9
43,5
48,3
49,4
40,8
36,2
30,8
46,5
44,1
39,1
36,1
31,6
36,8
35,3
29,9
*27,7
*21,3
29,5
*26,5
*19,9
*18,4
*17,6
*23,1
*23,2
*22,9
*22,9
*22,9
58,1
56,7
53,0
51,5
47,6
50,6
49,7
44,5
42,7
38,0
5,0 V
4,0 V
19,4 / 25,1
13,4 /18,6
32,1
*27,0
/s)
3
80
/s
3
4,0 V
3,0 V
19,1
13,7
*31,6
*30,3
44,1
40,4
37,6
28,7
*25,3
*17,6
*25,4
*16,8
*13,9
*12,2
*17,6
*17,5
*22,9
*22,9
45,3
*41,2
*33,5
*28,9
3,0 V
8,0 / 13,1
*24,4