130 E R
(electric radiator model)
• Maximum air flow 130 dm
• Separate 4-step fan speed controller.
• Supply air filtering G3 and F7.
• Comes standard with in-built heat recovery bypass (for summer use).
• Post-heating with electric or liquid radiator (VKL).
• Preheating (option) VALLOX 1000.
• Defrost automation.
• Fireplace switch function.
• Maintenance switch.
• Silencer unit (option).
• Ceiling mounting plate (option).
• Available as both R and L models.
• 8-step autotransformer enables power selection over a wide range.
• Connection for remote monitoring / remote use with the VALLOX 1993A YK control centre.
• Can be controlled with cooker hoods PTXP i 130 / PTXPA i 130.
Technical specifications
Fans
Heat recovery
Heat recovery bypass
Post-heating
Filters
Weight
Maintenance switch
Power adjustment
Input power and data
Options
© VALLOX • We reserve the right to make changes without prior notification.
The figures show R models. In
the L model duct outlets are in
the opposite order.
(See page 2.)
3
/s, 50 Pa ductwork pressure loss.
Supply air
210 W
105 dm
Extract air
210 W
125 dm
Plate heat exchanger, efficiency more than 60%
Summer / winter damper
Electric 1000 W radiator or water radiator (VKL)
Supply air
G 3 + F 7
G 3
Extract air
57 kg
Door switch
Separate 4-step speed controller, control centre 1993A YK
or cooker hoods PTXP / i 130 or PTXPA / i 130
230 V, 50 Hz, 1.35 kW, 5.9 A. IP 34
Filter guard
Preheating, VALLOX 1000
Fireplace switch function
Silencing unit
Ceiling mounting plate
VKL
3
/s 100 Pa
/s 100 Pa
3
• 1.09.84E
• 28.10.2008
© VALLOX
Code 3500 E
130 E VKL R
(water radiator
model)

Advertisement

Table of Contents
loading

Summary of Contents for Vallox 130 E

  • Page 1 • Available as both R and L models. • 8-step autotransformer enables power selection over a wide range. • Connection for remote monitoring / remote use with the VALLOX 1993A YK control centre. • Can be controlled with cooker hoods PTXP i 130 / PTXPA i 130.
  • Page 2: Technical Specification

    Summer / winter damper Overheat protection reset button Connection outlets ø 160 mm with seals Summer / winter damper handle Wall bracket Self-actuated one-way dampers (only the VKL model) © VALLOX • We reserve the right to make changes without prior notification.
  • Page 3 (10 m sound absorption) ADJUSTMENT POSITION / VOLUME FLOW RATES (supply / extract) 35/37 l/s 61/63 l/s 86/88 l/s 112/115 l/s , dB(A) © VALLOX • We reserve the right to make changes without prior notification.
  • Page 4 5 (15 l/s) 6 (18 l/s) 7 (21 l/s) 8 (24 l/s) 10 m sound rate (air flow volume to the room) absorption VALLOX 130 E + VALLOX SILENCER © VALLOX • We reserve the right to make changes without prior notification.
  • Page 5 /s / 36/24 47/49 56/42 75/49 85/73 93/95 108/126 PRESSURE, Pa Medium frequency of the octave band, Hz 1000 2000 4000 8000 , dB total , dB(A) total © VALLOX • We reserve the right to make changes without prior notification.
  • Page 6 Cooker hood PTXP /I 130, PTXPA /I 130 FILTERING VALLOX 130 E features both extract and supply air filtering before the fans and the heat recovery cell. The unit comes standard with a F7 fine filter (B), which captures fine dust, pollen and dust not seen to the eye, and G3 coarse filters (A) for insects and heavy pollen and room dust, for instance.
  • Page 7: Heat Recovery Bypass

    In summer use when it is warm outside, it is unnecessary to heat outdoor air. The heat recovery cell is then bypassed in VALLOX 130 E with the standard damper (A). The position of the damper can be changed using the handle (B). In the summer position air flow through the cell is prevented, and heat recovery bypass is activated.
  • Page 8 POST-HEATING Electric radiator VALLOX 130 E comes standard with a 1000 W post-heating radiator T (page 2, item 4). Supply air temperature is adjusted at the thermostat inside the unit (page 2, item 12). Adjustments can be made within the range of 0...25 °C. In summer when heat recovery cell bypass is activated, the thermostat has to be set at 0 °C.
  • Page 9 Curve 4 A 1000 W post-heating radiator can heat e.g. 100 l/s air Temperature of outdoor air coming to the unit by circa 8 °C at most. © VALLOX • We reserve the right to make changes without prior notification.
  • Page 10 KR Connection box (below the unit) KK Operating switch Fireplace switch, option. For instance a 15-minute timer with opening points. Mounted to replace wire 7-8 KR Connection box (below the unit) © VALLOX • We reserve the right to make changes without prior notification.
  • Page 11: External Electrical Connections

    PTXP / I 130 DISTRIBUTION VALLOX 130 E REMOTE MONITORING PANEL CONTROL CENTRE remote monitoring OPERATING STATUS DATA FILTER QUARD OPERATING STATUS DATA VALLOX 1993 A YK © VALLOX • We reserve the right to make changes without prior notification.
  • Page 12 LP1, preventing radiator surface temperature from exceeding the Overheat protector (incl. in LP1) 90 ˚C, manually reset threshold. As temperature exceeds the threshold, radiator overheat Regulating thermostat Vallox thermostat 0…40 ˚C Option © VALLOX • We reserve the right to make changes without prior notification.
  • Page 13 VALLOX 130 E OPERATION AND FUNCTIONAL DIAGRAM FOR VALLOX 130 E VKL / water radiator CONTROL DIAGRAM VALLOX 130 E VKL / post-heating – fluid radiator DISTRIBUTION 10 A 10 A / 16 A PANEL VALLOX 130 E INTERNAL ELECTRICAL AND...
  • Page 14: Location And Mounting

    LOWER EDGE OF BRACKET CONDENSING WATER CONNECTION AND WATER SEAL Electric wires can be taken out from ELECTRICAL CONNECTION the corners or from the middle LOCK MOUNTING © VALLOX • We reserve the right to make changes without prior notification.
  • Page 15 Wall mounting plate Ceiling mounting plate (optional) NOTE! FILTER Attaching the ceiling mounting plate to the unit © VALLOX • We reserve the right to make changes without prior notification.
  • Page 16: Wall Construction

    ELECTRICAL CONNECTION the corners or from the middle LOCK MOUNTING Vallox Oy FI-32200 Loimaa Finland Telephone +358 2 7636 300 Fax +358 2 7631 539 Internet: www.vallox.com. © VALLOX • We reserve the right to make changes without prior notification.