Adjustment of supply
air temperature
Fireplace switch, fl ush
mounting (option)
Supply and extract
air fl ow adjustment
potentiometer
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack
of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand
Cleaning and user maintenance shall not be made by children without supervision.
2
2
Fan speed adjustment
The fan speed of a Vallox ventilation unit can be controlled with a control switch (option), with
a separate cooker hood (option) or directly with a 0–11,4 V voltage signal.
Speeds 1, 2, 3 and 4 can be selected at the control switch.
1.
Operation during absence. When the dwelling is empty, ventilation can be reduced
temporarily.
2–3. Normal operation. In normal operation, air has to be replaced once every two hours.
4.
Boosted operation. Cooking, taking a sauna bath, washing, drying clothes, using
the toilet, having guests or a corresponding situation may cause a need for higher
ventilation than in normal operation.
ventilation than in normal operation.
ventilation than in normal operation.
Four-step control switch
Four-step control switch
Four-step control switch
Adjustment of supply air temperature and summer/winter
function
The temperature of air coming to the dwelling can be adjusted between circa +10 °C and
+30 °C. The midpoint of the adjustment range is circa +20 °C. When supply air temperature
adjustment has been turned in the OFF position, post-heating is not active. This means that
summer function is activated for the ventilation unit. The unit has a motorised summer/winter
function. When the summer function is on, the heat recovery cell is bypassed as soon as
outdoor air temperature has risen above +14 °C. When outdoor air temperature goes below
+12 °C, the unit starts to recover heat. When supply air temperature adjustment is in the
AUTO position, automatic function is activated for the unit. In this case, the setpoint for post-
heating is +17 °C and the heat recovery cell is bypassed automatically according to outdoor
temperatures as indicated above. When the unit bypasses the heat recovery cell, in which
case summer function is activated, post-heating is off.
Fireplace switch function
It is possible to connect a timer-operated switch to the unit. The switch stops the extract air fan
during the time when the fi replace is heated. NOTE! The starting of the extract air fan may
weaken draught in the fi replace! In winter, this situation may disturb the winter function of the
unit. The situation will normalise in a while, after the fi replace function stops.
Winter function of ventilation unit
A threshold value has been set at the factory for the freezing of the heat recovery cell. When
the threshold is exceeded, the ventilation unit starts to melt the heat recovery cell by guiding
outdoor air fl ow to bypass the heat recovery cell.
A normal melting period takes from 15 to 45 minutes depending on the extent of ice on
the heat recovery cell and on the amount of extract air fl ow. The unit has been optimised to
operate on the factory settings in normal operation in dwellings and detached houses. The
winter function parameters can be adjusted for extreme conditions, such as a swimming bath,
but even then it is advisable to contact Vallox Maintenance.
Adjustment of relationship between supply and extract air
This feature may be useful when adjusting air fl ows at the valves during mounting. After the
valves have been adjusted, a user does not need, and must not, touch the adjustment. When
needed, supply or extract air fl ow can be reduced at the potentiometer.
When the potentiometer is approximately halfway, supply and extract air fl ow have not been
reduced. Turning the potentiometer anticlockwise reduces air fl ow on the supply side, and
turning it clockwise reduces air fl ow on the extract side.

Maintenance reminder

The unit reminds of the need for maintenance every six months if an indicator (not standard)
has been connected to the connectors of the fault signal relay. The indicator then blinks at
one-second intervals. The maintenance reminder is reset when the door of the ventilation unit
is opened. See the maintenance instructions for information on the necessary maintenance
activities.
the hazards involved.
Children shall not play with the appliance.
© VALLOX • We reserve the right to make changes without prior notice.
© VALLOX • We reserve the right to make changes without prior notice.
OPERATING INSTRUCTIONS
Cooker hood PTXPA-MC
Cooker hood PTXPA-MC
What the units include can vary depending on the sales area.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tsk multi 80 mc

Table of Contents