Vallox TSK Multi 80 MC R Instructions For Use And Maintenance Manual

Vallox TSK Multi 80 MC R Instructions For Use And Maintenance Manual

Supply / extract ventilation with heat recovery for dwellings in blocks of flats and terraced houses
Hide thumbs Also See for TSK Multi 80 MC R:

Advertisement

Quick Links

• 1.09.380E
• 20.06.07
© VALLOX
CODE 3468
Supply / extract ventilation
with heat recovery
for dwellings in blocks of flats
and terraced houses
© VALLOX • We reserve the right to make changes without prior notification.

Advertisement

Table of Contents
loading

Summary of Contents for Vallox TSK Multi 80 MC R

  • Page 1 • 1.09.380E • 20.06.07 © VALLOX CODE 3468 Supply / extract ventilation with heat recovery for dwellings in blocks of flats and terraced houses © VALLOX • We reserve the right to make changes without prior notification.
  • Page 2: Main Parts

    (the most common way of abating cooking smokes in blocks of flats). Small detached houses and terraced houses are normally equipped with a separate cooker hood. © VALLOX • We reserve the right to make changes without prior notification.
  • Page 3 3. An open window also lets in noise pollution. 4. During summer, door / window ventilation may bring in air that is warmer than that in the dwelling. © VALLOX • We reserve the right to make changes without prior notification.
  • Page 4: Ventilation System

    Also, during the heating season indoor air humidity may condense in the ducts and structures and therefore cause humidity damage. © VALLOX • We reserve the right to make changes without prior notification.
  • Page 5 (or has changed during the initial adjustment) and select speeds shown against a white background instead. Voltage changes are also made by an expert, not the user himself. © VALLOX • We reserve the right to make changes without prior notification.
  • Page 6 2…14 °C. The water radiator may be controlled by a self-actuated thermostat, which has been installed inside the ceiling behind the unit, or inside the room. Post-heating does not require special maintenance. © VALLOX • We reserve the right to make changes without prior notification.
  • Page 7 VALLOX TSK INSTRUCTIONS FOR USE Adjustment of ventilation power VALLOX TSK ventilation unit can be controlled with either a cooker hood or a separate control centre. Cooker hood control The cooker hood is connected to the ventilation unit and is used to control air circulation in the whole dwelling.
  • Page 8 Cooking fumes are taken out with a cooker hood or an integrated hood and ventilator. For more instructions, see the instructions of the equipment in question. Detailed instructions for special control centres are available. © VALLOX • We reserve the right to make changes without prior notification.
  • Page 9: Maintenance Instructions

    F is) in the bottom reservoir is not clogged. Test it by pouring water into the reservoir. Do not let water flow into electrical devices. © VALLOX • We reserve the right to make changes without prior notification.
  • Page 10 Keep the unit clean to ensure its flawless operation and hygiene. After maintenance • Switch the unit on at the maintenance switch. • Ensure that the fans rotate. -• Close the doors. © VALLOX • We reserve the right to make changes without prior notification.
  • Page 11: Valve Operation

    This dust sticks to the ceiling or the wall caused by the flow coming from the valve. © VALLOX • We reserve the right to make changes without prior notification.
  • Page 12: Troubleshooting

    0 °C. At 0 °C freezing is likely; at 10 °C no freezing occurs but extract air can be too warm when going out. According to the factory setting, the antifreeze thermostat works at 4 °C. Vallox Oy FI-32200 Loimaa Finland Telephone +358 2 7636 300 Fax +358 2 7631 539 Internet www.vallox.com.

Table of Contents