Vallox TSK Multi 80 MC R Manual

Low-energy ventilation unit with heat recovery
Hide thumbs Also See for TSK Multi 80 MC R:

Advertisement

Quick Links

Manual
Low-energy ventilation unit with heat
recovery
Model
Document
TSK Multi 50 MC
D2585
TSK Multi 80 MC
Valid from
15.1.2018
Types
3603
Updated
3602
29.1.2018

Advertisement

Table of Contents
loading

Summary of Contents for Vallox TSK Multi 80 MC R

  • Page 1 Model Document TSK Multi 50 MC D2585 TSK Multi 80 MC Valid from 15.1.2018 Types 3603 Updated 3602 29.1.2018 Manual Low-energy ventilation unit with heat recovery...
  • Page 2 Vallox ProControl control panel (ordered separately) Vallox Capto PTC EC Vallox X-Line PTXP MC (optional) Vallox X-Line PTXPA MC Vallox Capto PTC EC control hood,  (optional) Vallox X-Line PTXP MC control hood, or Vallox X-Line PTXPA MC control hood (ordered separately) WARNING! The unit is not intended for use by children under 8 or by persons with reduced sensory, physical or mental capabilities, or whose lack of knowledge and experience do not ensure safe operation of the unit. ...
  • Page 3: Fan Speed Adjustment

    FAN SPEED ADJUSTMENT The fan speed of the Vallox ventilation unit is adjusted using a four-step control (optional). The available speed options of the control switch are 1, 2, 3, and 4: Away mode. The ventilation efficiency can be temporarily reduced when the apartment is unoccupied.
  • Page 4: Maintenance Reminder

    The maintenance reminder can also be set off manually. The Vallox Simple Control control panel, Vallox Capto PTC EC control hood: and the Vallox X-Line PTXP MC and • The damper is closed, then open-closed-open PTXPA MC control hoods, VAK 0-11,4 VDC: •...
  • Page 5: Troubleshooting Table

    The safety switch (S) automatically turns off the power In the L model, the parts are mirrored when the door of the Vallox TSK Multi 50/80 MC ventilation unit is opened. Always disconnect the power plug before starting the Vallox TSK Multi 50/80 MC ventilation unit maintenance.
  • Page 6: Condensing Water

    HEAT RECOVERY CELL Check that the heat recovery cell (D) is clean roughly once a year when the filters are being replaced. Clean by washing as required. • Pull the coarse filters including the frames out of the unit (A and C). Also remove the fine filter, if any (C). •...
  • Page 7 5. Tilt the fan 5,. Turn the fan 90° and tilt it forward to pull it forward to pull it out of the unit. out of the unit. Install the fan beds in a reverse order. © Vallox Oy - All rights reserved...
  • Page 8 VALLOX TSK MULTI 50 MC Air flow Supply air TECHNICAL SPECIFICATIONS measurement Product title Product number HVAC code Extract air Vallox TSK Multi 50 MC R 3462600 7912020 points Vallox TSK Multi 50 MC L 3462700 7912023 Air volumes Supply air...
  • Page 9 Total height with an elbow 264 mm for installation: for installation: 47mm 70mm Total height with the Vallox Silent Klick water seal is 279 mm SOUND VALUES Sound power level in the supply air duct Sound power level in the extract air duct...
  • Page 10 VALLOX TSK MULTI 80 MC Air flow Supply air TECHNICAL SPECIFICATIONS measurement Extract air Product title Product number HVAC code Vallox TSK Multi 80 MC R 3478000 7912024 points Vallox TSK Multi 80 MC L 3478100 7912025 Air volumes Supply air...
  • Page 11 Total height with an elbow 321 mm Water seal Space required Space required for installation: for installation: Total height with the Vallox Silent Klick 47mm 70mm water seal is 336 mm SOUND VALUES Sound power level in the supply air duct...
  • Page 12: Electrical Connection

    ELECTRICAL CONNECTION...
  • Page 13: Electrical Connections

    3 and 5 from the MC unit’s control panel connector EXTERNAL ELECTRICAL CONNECTION with the Vallox Simple Control control panel / Vallox PTXP MC, Vallox PTXPA MC cooker hood Control signal S Internal connection 11.2 Vdc / +...
  • Page 14 EXTERNAL ELECTRICAL CONNECTION with Vallox ProControl control panel Wiring between the control panel and the ventilation unit, NOMAK 2x2x0.5+0.5 Ventilation unit cable Control panel connector leave disconnected S/DI2 Cable types specified in the drawing are indicative The phase of 24 VAC feed is connected...
  • Page 15: Installation Site

    INSTALLATION SITE Mounting The Vallox TSK Multi 50/80 MC is normally installed on the Vallox TSK Multi 50/80 MC must be installed in a location ceiling using the four mounting hooks delivered with the unit. where the temperature remains above +10 °C. When the...
  • Page 16: Exploded View And Parts List

    (Vallox TSK Multi 80 MC) Finger screw for the door ................990698 15 Filter stand (G4, supply) 500mm (Vallox TSK Multi 50 MC) ....3356400 Heat recovery cell (Vallox TSK Multi 50 MC)..........933120 15 Filter stand (G4, supply) 580mm (Vallox TSK Multi 80 MC) ....3352700 Heat recovery cell (Vallox TSK Multi 80 MC) ..........933130...